04 lifting options, 05 input power connections – Tweco 75XL Plus PAK Master Manuel d'utilisation

Page 20

Advertising
background image

INSTALLATION

3-2

Manual 0-2807

3.04 Lifting Options

WARNINGS

Do not touch live electrical parts.

Disconnect input power conductors from de-ener-
gized supply line before moving unit.

This unit is equipped with one handle mounted onto the
top of the enclosure for hand carrying purposes.

WARNING

FALLING EQUIPMENT

can cause serious per-

sonal injury and equipment damage.

• Lift unit with the handle on top of the enclosure.

• Only persons of adequate physical strength should

lift the unit.

• Use hand cart or similar device of adequate capac-

ity.

• If using a fork lift vehicle, place and secure unit on

a proper skid before transporting.

• This unit has a handle mounted on top of the enclo-

sure for hand lifting only. Be sure unit is lifted and
transported safely and securely.

WARNING

HANDLE

is not for mechanical lifting.

3.05 Input Power Connections

The Power Supply accepts input voltages from 208V to
460V. Input can be 50 or 60 Hz, single-phase or three-
phase.

The Power Supply is factory-wired for 230V single-phase
or 460V three-phase input depending on the order. For
any other input voltage, the Power Supply must be
changed using the procedure in Section 3.06.

A. Electrical Connections

The power source must conform to local and national elec-
tric codes. Recommended circuit protection and wiring
requirements are shown in Appendix I.

B. Opening Power Supply Enclosure

The left side panel of the Power Supply must be removed
to gain access to the input power connections and the
input voltage selection.

WARNING

Disconnect primary power at the source before as-
sembling or disassembling the Power Supply, torch
parts, or torch and leads assemblies.

1. Remove the five screws which secure the left side

panel (viewed from front of unit) to the frame as-
sembly.

A-02752

Ground

Wire

Screws

(5 places)

Left Side

Panel

Figure 3-1 Removing Left Side Panel

NOTE

There is a ground wire connection to the Left Side
Panel on the inside of the unit.

2. Carefully pull the Left Side Panel up and away

from the unit to gain access to the inside of the
unit.

Advertising