Tweco 75XL Plus PAK Master Manuel d'utilisation

Page 30

Advertising
background image

INSTALLATION

3-12

Manual 0-2807

ARC V.

START

OK TO

MOVE

+

1

2

3

4

5

6

-

+

-

A-02754

Figure 3-16 Terminal Block Positions

NOTES

ARC V+ Power supply positive output voltage
(work lead) connection to TB position 1 through a
100k resistor.

ARC V- Power supply negative output voltage
(torch electrode) connection to TB position 2
through a 100k resistor.

START + signal at TB position 3, 15 vdc at 10 ma,
must be brought low by connecting it to START -
at TB position 4, using a switch or relay contact,
to start the plasma torch.

OK-To-Move is a relay, rated at 115 VAC/28 vdc
at 2A, connected to TB positions 5 and 6 which
closes for the OK-To-Move signal when the cut-
ting arc is on.

Make sure all connections to the Terminal Block
(TB) are secure.

f. Reinstall the terminal block into the socket on

the Filter/Voltage Divider PC Board.

g. Secure the CNC cable by tightening the strain

relief.

h. Reinstall the Left Side Panel.

B. Optional Standoff Control SC11 Cable

The Standoff Control SC11 automatically finds height and
maintains torch standoff with a high speed torch lifter
motor. The unit consists of a remote operator's control,
torch lifter motor, and all cables required for installation.
It is ordered and shipped separately. Refer to the Stand-
off Control SC11 Instruction Manual for more informa-
tion.

The standoff control remote cable connects to the recep-
tacle J22 (CNC Control) on the rear panel of the Power
Supply.

J22

CNC Connector

A-02759

CNC or Remote Hand

Pendant Control Cable

Figure 3-17 Standoff Or Hand Pendant Control

Interface Connection

C. Optional Remote Hand Pendant Control

For automated systems, the optional Remote Hand Pen-
dant Control allows the operator to control system start
and stop functions from a remote location.

Connect the Remote Hand Pendant cable connector to
the receptacle J22 (CNC Control) on the rear panel of the
Power Supply.

Advertising