Tweco 75XL Plus PAK Master Manuel d'utilisation

Page 16

Advertising
background image

INTRODUCTION

2-2

Manual 0-2807

6. Duty Cycle (Refer to NOTE)

NOTE

The duty cycle will be reduced if the primary in-
put voltage (AC) is low or the DC voltage is higher
than shown in the chart.

Ambient

Temperature

Duty Cycle

40%

65%

100%

Current

n/a

60 Amps 50 Amps

DC Voltage

n/a

104 vdc

104 vdc

PakMaster 75XLP Automated

Power Supply Duty Cycle

104° F

(40° C)

7. Cut Capacity (Mild Steel)

Production:

5/16 inch (7.9 mm)

Genuine:

3/4 inch (19.1 mm)

Severance:

1 inch (25.4 mm)

8. Pilot Circuitry

Capacitive Discharge (CD), Pulsed DC

9. Weight

64 lbs (29 kg) w/work lead

71 lbs (32 kg) w/work lead and 25' Torch & Lead

10. Overall Dimensions

19" (482 mm) High x 10.5" (267 mm) Wide x 24.8"
(630 mm) Long

Overall dimensions are with Handle, Gas Regulator/
Filter Assembly and Two Stage Air Filter installed.

B. Gas Regulator/Filter Assembly

Specifications

The following specifications apply to the Gas Regulator/
Filter Assembly only:

1. Gas regulator maximum gauge pressure

160 psi (11 bar)

2. Maximum input gas pressure

125 psi (8.6 bar)

3. Filter

Coalescent type filter

C. Two Stage Air Line Filter Specifications

The following specifications apply to the Two Stage Air
Line Filter Assembly only:

NOTE

The two stage air line filter is for use on systems
using compressed air.

1. Air Flow

15 scfm (425 lpm)

NOTE

Depending on the moisture in the air source the
weep drain on the bottom of the Filter should be
left open 1/4 turn at all times. The weep drain will
allow 10 scfh (10.7 lpm) of air to escape using 100
psi line pressure in the closed position. This will
allow water, oil and contamination to escape from
the filter.

2. Maximum input pressure

250 psi (17.2 bar)

3. Dew Point

10° to 35° F (-12° to 1.7° C) @ Atmospheric Pressure

4. Filtration

5 micron

Advertising