background image

APPENDIX A-6

Manual 0-4764

APPENDIX 5: CNC - CONTROL MODULE BOARD PCB CONNECTIONS

Art # A-04900_AC

TB1-1 E-Stop (Com)

TB1-2 E-Stop

TB1-3 OK 2 Contacts 24V Max
TB1-4 Stop Latched

TB1-5 Start / Stop Ret

TB1-6 Start / Stop or Start Latched (NO)

TB1-7 Divided Arc Voltage (-)

TB1-8 Divided Arc Voltage (+)

TB1-9 Remote Analog Current Control (0-10V) (-)

TB1-10 Remote Analog Current Control (0-10V) (+)

TB1-11 +10V @ 10ma For Remote CC POT

TB1-12 OK 2 Contacts 24V Max

TB2-1 Hold Start (-)

TB2-2 Hold Start (+)

TB2-3 Preflow On (-)

TB2-4 Preflow On (+)

TB2-5

TB2-6 Pilot On (Relay Contacts NO)

TB2-7

TB2-8 Pilot On (Relay Contacts NO)

TB2-9

TB2-10 OK to Move (Contacts or DC Volts) (-)

TB2-11

TB2-12 OK to Move (Contacts or DC Volts) (+)

TB2

TB1

Sustained Start / Stop

TB1-5

TB1-6

Momentary Start / Stop

TB1-4

TB1-5

TB1-6

Stop

Start

Start / Stop Circuit Configurations

These points are jumpered together at the factory.
Remove the jumper to use existing E-Stop circuits.

TB3

1

TB3-1

TB3-2

}

Marking Input