3-1 INSTALLATION

SECTION 3: INSTALLATION

3.01 Installation Requirements

Electric Supply

The electrical supply network, the gas and water supply system must meet local safety standards. This

conformity shall be checked by qualified personnel.

Auto-Cut 100 Power Supply

Input

Power Input

Current

Suggested Sizes (See Note)

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

208

50/60

23

64

80

#4

1

230

50/60

24

60

75

#4

1

400

50

28

40

50

#6

1

400 (CE)

50

28

40

50

#6

1

460

50/60

26

33

40

#8

1

Line Voltages with Suggested Circuit Protection and Wire Sizes

Based on National Electric Code and Canadian Electrical Code

1

Extra Hard Usage Type SO, SOW, SOO, SOOW, ST, STW, STO, STOW, STOO, STOOW

CAUTION

Fuse and wire sizes are for reference only. The installation must conform to national and local codes for the type

and method of wire being used.

Gas Supply

The customer must supply all gases and pressure regulators. Gases must be of high quality. Pressure

regulators must be double-stage and installed as close as possible to the gas console. Contaminated gas

can cause one or more of the following problems:

• Reduced cutting speed
• Poor cut quality
• Poor cutting precision
• Reduced consumables life.
• Oil or grease contamination from compressed or bottled air can cause fires in conjunction with oxygen.

Cooling System Requirements

Coolant must be added to the system on installation. The amount required varies with torch leads length. Ther-

mal Dynamics recommends the use of its coolants 7-3580 and 7-3581 (for low temperatures).

Coolant Capabilities

Cat. Number and Mixture

Mixture

Protects To

7-3580 'Extra-Cool

TM

'

25 / 75

10° F / -12° C

7-3581 'Ultra-Cool

TM

'

50 / 50

-27° F / -33° C

7-3582 'Extreme Cool

TM

'

Concentrate*

-65° F / -51° C

* For mixing with D-I Cool