05 primary power connections, Primary power connections -5 – Tweco 100 Auto-Cut Manuel d'utilisation

Page 29

Advertising
background image

Manual 0-4764

3-5 INSTALLATION

3.05 Primary Power Connections

The primary power cable must be supplied by the end user and connected to the power supply. Refer to local

and national electrical codes for suggested cable and fuse sizes.

Remove the connections cover on the rear of the Power Supply. Use caution when removing the panel; there is

a ground wire connected to the inside of the panel. Do not disconnect this wire.

Connections Cover
(Removed)

Connection Panel

Art # A-04827

Check / Adjust Input Voltage Configuration

(208-230 / 460 V Only)

1. The power supply includes a voltage

configuration board which must be

positioned to match the primary input

voltage. Remove the power supply

left side panel and locate the voltage

configuration board. The input voltage

configuration is shown at the top of the

board.

2. If necessary, disconnect the jumper from

the top-right corner of the board, remove

the board and re-install with the correct

input voltage shown at the top of the

board. Reconnect the jumper to the top-

right corner of the board.

3. Re-install the power supply side panel.

Art # A-04856_AB

1. Unplug connector

2. Remove bolts.

3. Invert board.

4. Re-install board.

5. Plug in connector.

208/230V / 460V

Input Voltage Board

(Shown in 460V Position)

Inverter Module

Advertising