TORCH MAINTENANCE

7-4

Manual 0-4764

CAUTION

The cartridge assembly must cover the O-Ring on the torch head.

Do not force the cartridge if it will not tighten fully. Remove the cartridge assembly and gently clean the threads on

the torch head with a wire brush. Apply oxygen-compatible lubricant (supplied with the torch) to the threads.

Torch Head O-Ring

Torch Head

Art # A-07202

0.063 - 0.083"
(1.6 - 2.1 mm)

Protrusion

Installing Assembled Cartridge Onto Torch Head

3. Slide the ohmic clip over the shield cup if using ohmic torch height control sensing.

NOTE

Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the ohmic

sensing circuit.

Ohmic Clip

Art # A-03393_AB

4. Connect the wire lead from the height finder to the ohmic clip.