Tweco 100 Auto-Cut Manuel d'utilisation

Page 55

Advertising
background image

Manual 0-4764

4-9 OPERATION

Fault Code Key

Error Code Error

Remedy / Comments

3-1

Gas Control Conn Fault -

Connection missing or lost

3-3

Plasma Pressure Low

4-1

Coolant Level Low

(before arc start)

Check coolant level in tank, add as needed.

4-2

Low or Missing Coolant

Flow (> 15 seconds when

arc off,

or

ASAP when flow <0.35 gal/

min during active arc,

or

when flow is 0.35 - 0.7 gal/

min for > 3 seconds

Check coolant level in tank, add as needed.

4-3

Coolant Overheated

(over 158° F [70° C])

Coolant temperature must drop by 9° F (5° C)

to clear over temp condition

4-4

Cooling System Not Ready.

Pump has run >30 sec w/o

reaching minimum flow

requirement.

Recycle power or cycle plasma enable / E-Stop.

4-5

Low Coolant Warning

(during cut)

Warning does not stop cut. Stop cut, shut off input

power, add coolant to tank.

6-1

CCM Analog Voltage Error Contact Thermal Dynamics.

6-2

CCM Analog to Digital

Converter

Contact Thermal Dynamics.

6-3

Coolant Flow Circuit Error

Contact Thermal Dynamics.

6-4

CCM Data Memory Error

Contact Thermal Dynamics.

Advertising