Installation continued – Garland E20 SERIES ELECTRIC UNITS Manuel d'utilisation

Page 9

Advertising
background image

Part # P66 (01/25/08)

Page 9

Broilers Without Splatter

Guard

Broilers With

Splatter Guard

Sides

9” (229mm)

Sides

3” (76mm)

Back

9” (229mm)

Back

1” (25mm)

Electrical Connections

For supply connection, use wire suitable for 75°C (167°F).

Electrical connection may be made though the knockout at
the rear of the unit to the terminal block located (E22-12B &
E22-24B) on the main bottom, left side, or (22-36B) on the
main bottom center. Access to the terminal box is gained by
removing the grease hopper (grasp upper front panel and
withdraw). Remove two 10-24 hex nuts securing the terminal
box cover, lift and remove.

Controls

Infinite switches are used to control the heating units:

Hi to 5

High heat

5 to 3

Medium heat

3 to Lo

Low heat

Setting of switches between the numbers will give
intermediate heat. Switches are reversible and may be
turned right or left.

Hot Plate – Model E24-12H

Serial Plate Location

The serial plate is located on the main back.

Wall Clearances

Do not install closer to a wall of combustible material than:

Sides

1” (25mm)

Back

1” (25mm)

Electrical Connections

For supply connection, use wire suitable for 75°C (167°F).

Electrical connection may be made though the knockout
at the rear of the unit to the terminal block located on the
inside left rear of the unit. Access to the terminal box is
gained by removing the back cover plate at the rear of the
unit.

Controls

Infinite switches are used to control the heating units:

Hi to 5

High heat

5 to 3

Medium heat

3 to Lo

Low heat

Setting of the switches between the numbers will give
intermediate heat. Switches are reversible and may be
turned right or left.

Fryers – Model E24-31F, E24-31SF,
E24-31FBL, E24-31SFBL, E18F,
E18SF, E18FBL & E18SFBL

Serial Plate Location

For the E24 series, the serial plate is located on the back of
the control wiring compartment, to access remove fry bowl.

For the E18 series the serial plate is located on the top of the
control wiring compartment, to access remove the grease
drawer or fryer bowl.

Wall Clearances

Do not install closer to a wall of combustible material than:

E24 Series

E18 Series

Sides

0”

Sides

1” (25mm)

Back

0”

Back

1” (25mm)

Electrical Connections

For supply connection use wire suitable for 60°C (140°F).

Electrical connection may be made though the knockout at
the rear or bottom of the unit to the terminal block, located
on the inside rear of the unit. Access to the terminal box is
gained by removing the fryer bowl. Remove the rear shield,
remove three 10-24 hex nuts securing the terminal box
cover, remove the terminal box cover.