Installation continued – Garland E20 SERIES ELECTRIC UNITS Manuel d'utilisation

Page 11

Advertising
background image

Part # P66 (01/25/08)

Page 11

4. Carefully remove the thermostat dial, not disturbing the

dial setting.

5. Hold the dial shaft steady and with a screw driver,

turn the calibration screw located inside the dial shaft,
clockwise to decrease and counter-clockwise to increase
the temperature.

EG: 1/4 turn = 35°F (19.5°C)

6. Replace the thermostat dial and repeat steps 1 through 3

to verify the correct adjustment has been made.

Stock Pots Ranges –
Model E20-SP & E20-SPC

Serial plate location

The serial plate is located on the main front.

Wall Clearances

Do not install closer to a wall of combustible material than:

Sides

5” (127mm)

Back

5” (127mm)

Electrical Connections

For supply connection, use wire suitable for 90°C (194°F).

Electrical connection may be made through the knockout at
the rear of bottom of the unit to the terminal block, located
behind the lower front panel. Access to the terminal block is
gained by removing the 10-24 machine screws and hinging
the lower front panel down.

Controls

Stock Pot ranges are equipped with snap action thermostats
with dial setting marked 1 to 10.

1 –

260˚F (127˚C)

6 –

640˚F (338˚C)

2 –

340˚F (171˚C)

7 –

715˚F (379˚C)

3 –

410˚F (210˚C)

8 –

790˚F (421˚C)

4 –

490˚F (254˚C)

9 –

870˚F (466˚C)

5 –

565˚F (296˚C)

10 –

940˚F (504˚C)

Setting of the thermostat between the numbers will give
intermediate heat.

INSTALLATION continued

Advertising