Motec 103 – MoTeC M880 Manuel d'utilisation

Page 107

Advertising
background image

MoTeC

103

REF

(Magnetic)

Manifold

Pressure

Throttle

Position

2

56

49

18

26

AV 2

AV 1

50

AUX OUTPUTS

Stepper Motor, Relays or Valves

Injector 2

Ignition

System

See Detail
Drawings

14,15,19

- +

12 Volt
Battery

Chassis
Earth

12V

GND

20 Amp

Fuse

Refer to the
Trigger Drawings
for details

Sensors

Injectors

ECU

Connect in firing order

for sequential operation

2 nd

33

Injector 1

1 st

63

Injector 3

3 rd

66

Injector 4

4 th

42

Injector 6

6 th

24

Injector 5

5 th

57

Injector 7

7 th

62

Injector 8

8 th

8

Aux 2

9

Aux 1

43

Aux 3

Aux 4

65

Aux 6

59

Aux 5

58

Aux 7

23,32,41

Aux 8

5

Ignition 2

1

Ignition 1

4

Ignition 3

10

Ignition 4

25

Ignition 6

17

Ignition 5

Note 2

Note 3

Note 1

20 Amp

Fuse

+

_

SYNC
(Magnetic)

+

_

REF

(Hall or Optical)

56

49

8V Aux Power

REF

+

_

Sig

SYNC

(Hall or Optical)

+

_

Sig

SYNC

3 8V Eng

Air

Temp

28 AT 1

Engine

Temp

27 0V Eng

Lambda

1

54

LA1P

60

LA1S

Lambda

2

55

LA2P

61

LA2S

5V Eng

16

38 AT 2

34 5V Aux Power

Power to Auxiliary

sensors

0V Aux Power

11

DIGITAL
INPUTS

AT 4

AT 3

AT 5

AT 6

AV 8

30

39

29
37

44

Dig 1

Dig 3

Dig 4

46

45

52

53

ANALOG

TEMP INPUTS

ANALOG

VOLT INPUTS

Ignition

Switch

AV 7

35

AV 3

AV 5

AV 6

6

7

12

36

Note 2
To avoid the fuse blowing due to reverse

battery polarity use a diode activated relay
eg. Bosch 0332 014 112

Note 1

The Fuse is essential to ensure that the
ECU is not damaged by reversed battery

polarity

0V To Auxiliary
Sensors

Looking into
Connector
on ECU

47

48

40

31

13

Note 4

See drawing

X25 for wiring

details

64

Relays or Valves

20,21,22

CAN LO

CAN HI

RS 232 Rx

0V Comms

2
3
5

CAN Connector

Deltron

716-0-0501

1
4

3

5

Serial Connector

D9 female

Advertising