Do not install the Power Venter on incinerators, condensing type appliances or solid-fuel burning appliances. Only install the Power
Venter on John Wood Signature (JWS) Series water heaters.

1. “Qualified Installer” shall mean an individual properly trained and licensed.

2. Plan the vent system so that Code required distances are maintained from plumbing and wiring.

3. The Power Venter motor shaft must be mounted horizontally to ensure proper operation of the Fan Proving Switch and prevent

motor bearing wear.

4. Make certain the power supply is adequate for the fan motor requirements. Do not add the Power Venter to a circuit where the

total load is unknown.

5. Flue gas temperatures must not exceed 600°F. at the Power Venter inlet. Ambient temperatures must not exceed 104°F.

Temperatures above this range can cause a fire resulting in property damage, personal injury or death.

6. A safety inspection of an existing appliance must be performed before installation of the Power Venter as outlined in “Natural Gas

and Propane Installation Code, CAN/CSA-B149.1” or “National Fuel Gas Code, ANSI Z223.1 (NFPA 54)”, Appendix H, see
“Safety Inspection of a Previously Used Appliance” below.

1. The installer must read and follow these instructions carefully to assure proper installation and operation of the Power Vent kit.

2. The appliance may only be installed on the suction side of Power Venter.

3. The installer must notify the owner of the maintenance required with the use of the product.

4. The installer must shut off all electricity and gas to the appliance using the appliance circuit breaker/fuse for the electricity and shut

off valve in the supply line to the appliance for the gas before installation of the Power Vent kit.

(Perform prior to Power Venter installation)

The following procedure is intended as a guide to aid in determining that an appliance is properly installed and is in safe condition for
continuing use.

The following procedure is based on central furnace and boiler installations and it should be recognized that generalized procedures
cannot anticipate all situations. Accordingly, in some cases deviation from this procedure may be necessary to determine safe opera-
tion of the equipment.
a. Perform this procedure prior to any attempt at modifications of the appliance or installation of the Power Venter.
b. If it is determined there is a condition which could result in unsafe operation, shut off the appliance and advise the owner of the

unsafe condition.

Follow the steps below in making the safety inspection:

*SAFETY INSPECTION OF A PREVIOUSLY USED GAS APPLIANCE

INSTALLATION RESTRICTIONS

INSTALLER NOTES

WARNING

Improper installation, adjustment, alterations, service or maintenance can cause injury or property damage. Refer to this
manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

WARNING

• Failure to install, maintain and/or operate the Power Venter in accordance with manufacturer's instructions may result in

conditions which can produce bodily injury and property damage.

• The Power Venter must be installed by a qualified installer in accordance with these instructions and all local codes or

in their absence in accordance with the latest edition of “Natural Gas and Propane Installation Code, CAN/CSA-B149.1” or
“National Fuel Gas Code, ANSI Z223.1 (NFPA 54)”, the latest edition of “Canadian Electrical Code Part 1, (C22.1)” or “National
Electrical Code, (NFPA 70)”, and the Occupational Safety and Health Act (OSHA) when applicable. Improper installation can
create a hazardous condition such as an explosion, fire, electrical shock or carbon monoxide poisoning resulting in
property damage, personal injury or death.

• Disconnect the power supply when making wiring connections or when working around the fan wheel and motor.

Failure to do so can result in electrical shock, personal injury, death or property damage.