OPERATION menu

The underlining indicates the factory setting.

170

HUMID OPE

0000
0001

OFF

ON

This selects whether the unit is to continue operating when
condensation has formed.
0: The unit does not operate.
1: It operates even when condensation has formed but no

guarantees are made for its operation.

<Note>
Since tape damage or other problems may occur when “1: ON”
has been selected, the “0: OFF” setting should normally be used.

171

ALL STOP SEL

0000
0001

STOP

STILL

This selects the unit’s mode to be established when the ALL
STOP button has been pressed.
0: The unit is set to the STOP mode.
1: The unit is set to the still-picture (SHTL + 0.0, JOG STILL)

mode.

[

[

110

MEMORY STOP

0000
0001

OFF

ON

This selects the processing to be conducted when the counter
displays zeros in the CTL mode or during FF or REW.
0: The VTR is not shut down.
1: The VTR is automatically shut down.
<Note>

O

For the stop mode, either the stop or still-picture (SHTL + 0.0,
JOG STILL) mode is set depending on the setup menu item
No.315 (AFTER CUE-UP) setting.

O

When both the AUTO REW function and MEMORY function
have been selected, the AUTO REW function takes priority.

[

[

Item

Setting

No.

Superimposed

display

No.

Superimposed

display

Description of setting

V
T
R

1

V
T
R

2

172

VTR1 IN SEL

0000
0001

V1 IN
V2 IN

This selects the VIDEO/AUDIO input of VTR1 when the analog
signal input has been selected.
0: VTR1 IN serves as the VTR1 input.
1: VIDEO IN and AUDIO IN of VTR2 serve as the VTR1 input.
<Notes>

O

The unit will not operate when SDI signal input has been
selected.

O

This operation is not performed in the 625i mode.

[

173

BATTERY SEL

0000
0001
0002
0003
0004
0005
0006
0007
0008

10.8V
11.0V
11.2V
11.4V
11.6V
11.8V
12.0V
12.5V
13.0V

This selects the voltage threshold for warning when the DC supply
voltage has dropped.
(The unit’s power is automatically turned off when it drops to 10.6
V.)
0: When it has dropped to 10.8 V
1: When it has dropped to 11.0 V
2: When it has dropped to 11.2 V
3: When it has dropped to 11.4 V
4: When it has dropped to 11.6 V
5: When it has dropped to 11.8 V
6: When it has dropped to 12.0 V
7: When it has dropped to 12.5 V
8: When it has dropped to 13.0 V

[

174

SDI OUT

0000
0001

VTR1
VTR2

This selects the SDI output.
0: The VTR1’s signals are output.
1: The VTR2’s signals are output.

[