6technical characteristics – Radson 4 Zones RF Clock Manuel d'utilisation

Page 27

Advertising
background image

27

6

Technical characteristics

Environmental:
Operating temperature:
Shipping and storage
temperature:


0°C - 40°C

-10°C to +50°C

Electrical Protection
Installation Category
Pollution Degree

IP30
Class II
2

Measured temperature
precision

0.1°C

Power Supply
Operating life

2 AA LR6 1.5V Alkaline
~2 years

Sensing elements:

NTC 10k

at 25°C

Radio Frequency

868 MHz, <10mW.

Software version

Showed in the parameter
menu.

Vers xxx

Norms and
homologation:

Your thermostat has
been designed in
conformity with the
following standards or
other normative
documents:

EN 60730-1 : 2003
EN 61000-6-1 : 2002
EN 61000-6-3 : 2004
EN 61000-4-2 : 2001

EN300220-1/2
EN301489-1/3

R&TTE 1999/5/EC
Low voltage 2006/95/CE
EMC 2004/108/CE