Using Your AVU1500 with a

Home Automation System (optional)

AVU Special Features (Page 0x86)

Report ID #

Usage (usage ID)

Byte #

Unit

Comment

110

Stage 1 Battery Threshold (0x29)

1

%

R/W

111

Stage 2 Battery Threshold (0x29)

1

%

R/W

112

Stage 3 Battery Threshold (0x29)

1

%

R/W

113

Stage 1 Load Current (0x31)

1

Amps

R

114

Stage 2 Load Current (0x31)

1

Amps

R

115

Stage 3 Load Current (0x31)

1

Amps

R

117

Site Wiring Fault (0xFC)

1

R

118

Site Ground Fault (0xFB)

1

R

119

Stage 1 Remaining Time (0xFA)

2

Sec

R

120

Stage 2 Remaining Time (0xFA)

2

Sec

R

121

Stage 3 Remaining Time (0xFA)

2

Sec

R

122

Shutdown Override (0xF9)

1

R/W IN/Feature*

123

IR Shutdown Code Known (0xF8)

1

R IN/Feature*

124

IR Shutdown Code Broadcast at
Beginning of Stage N (0xF7)

1

Stage

Number

R

85

Source Change (0xF6)

1

IN*

86

Stage 1 startup/shutdown (0xF5)

1

R IN/Feature*

87

Stage 2 startup/shutdown (0xF5)

1

R IN/Feature*

88

Stage 3 startup/shutdown (0xF5)

1

R IN/Feature*

89

Overload (0xF2)

1

IN*

90

Battery Fully Charged (0xF1)

1

R IN/Feature*

91

Battery Needs Replacement

(0xF0)

1

IN*

92

Power Off Notification (0xFD)

1

IN*

IN* indicates this item is interrupt only, IN/Feature means this item supports both interrupt and feature.

• The PresentStatus in Power Status is a collection item that includes:

• VoltageOutOfRange: The input voltage is lower or beyond the

normal range. The UPS transfers to backup mode and supplies the
output power from battery.

• Buck: The input power is suppressing to normal range.
• Boost: The input power is boosting to normal range.
• Overload: The loading beyond the rating power.
• Standby: The UPS is in standby mode, which mans the UPS is not

turned on.

• OverTemperature: Over temperature.
• InternalFail: UPS general fail indication.
• BuzzerSilence: Indicates to support buzzer enable/disable

control item.

• Beeper: To indicate the UPS buzzer is silent or alarm.