Using Your AVU1500 with a

Home Automation System (optional)

Check Sum
Sum the bytes from “Header” to “Data”. Overflow ignored.
Notification
AVU models have the ability to send UPS data to PC regardless of any
pending polling commands from computer.
Power Configuration Controls (UsagePage=0x86)

Report ID#

Usage (usage ID)

Byte #

Unit

Comment

1

} ConfigVoltage (0x40)

1

Volt

R

2

} ConfigFrequency (0x42)

1

Hertz

R

3

} ConfigApparentPower (0x43)

2

VA

R

4

} ConfigBatteryVolt (0x44)

2

Volt

R

• ConfigVoltage:

Nominal value of the voltage.

• ConfigFrequency:

Nominal value of the frequency.

• ConfigApparentPower: Nominal value of the apparent power.
• ConfigBatteryVoltage: Nominal value of the battery voltage.

Power Device Identification (UsagePage=0x86)

• Model String Index: Index of a string descriptor describing model

names string. The UPS Model String may contain several model
names, each name is separated by a “/”. If this command comes
from the RS232, then UPS returns the Model String rather
than Index.

• Model String Offset: Offset of the UPS model name in the model

names string.

• UPSType:

• Low 4 bits Result

0: On-Line

1: Off-Line

2: Line-Interactive

3: Simple On-Line

4: Simple Off-Line

5: Simple Line-Interactive

• High 4 bits Result

Indicates the firmware version

Report ID #

Usage (usage ID)

Byte #

Unit

Comment

13

}Model String Index (0x75)

1

R

14

}Model String Offset (0x76)

1

R

15

}UPSType (0x7C)

1

R