37

INPUTS/OUTPUTS

Press menu/esc to select the desired menu


Use the keys up and down to display

Press enter to gain access to the mode for displaying inputs and outputs

The display shows

Use the keys up and down to scroll the data to display











C

Compressor

R

Door resistance

D

Defrost

A

Alarm

FE Evaporator fan

DI1

Inputs state micro

FC Condenser fan

DI2

Inputs state thermostat

L

Sterilization

FAN Evaporator fan speed


Press menu/esc to exit



PRINTER INSTALLATION


The printer is not supplied as standard equipment .
Should you purchase the printer, please follow the installation instructions to install.

Room

21°F

Probe

59°F

Room 21°F
Probe 59°F

Room: Room air temperature
Probe: Core temperature – see core probe section

DI1 DI2 FAN

0 1 80

C D FE FC L R A
1 0 0 1 1 0 0

Evap. 14°F
Cond. 70°F

Digital inputs state and evaporator
fan speed

Outputs state
1 = relay activated
0 = relay de-activated

Evaporator and Condenser temperature values

Inputs/Outputs

Esc

Food 93°F
External 90°F

Food: under surface probe – see core probe section
External: over surface probe – see core probe section