32

SERVICE

PARAMETERS


DESCRIPTION OF PARAMETERS

Parameter Description

Default

(BCF...)

Default

(BC...)

min MAX

POSITIVE QUICK COOLING

P01

Room SetPoint in pos. quick cooling, Soft phase

23°F

23°F

-22°F

86°F

P02

SetPoint in pos. quick cooling, Hard

-12°F

-12°F

-40°F

86°F

P03

Needle SetPoint in pos. quick cooling , Soft phase

37°F

37°F

-22°F

86°F

P04

Needle SetPoint in Hard quick cooling

68°F

68°F

-22°F

86°F

P05

Positive quick cooling duration

90min

90min

0min

900min

P06

Hard phase duration expressed as % in relation to P05

60%

60%

0%

100%

P07

Room SetPoint in pos. storing

36°F

36°F

-22°F

86°F

NEGATIVE QUICK COOLING

N01

Room SetPoint in neg, quick cooling

-12°F

-12°F

-40°F

86°F

N02

Needle SetPoint in neg. quick cooling

0°F

-0°F

-22°F

86°F

N03

Negative quick cooling duration

240min

240min

0min

900min

N04

Room SetPoint in neg. storing

-7°F

-7°F

-40°F

86°F

ALARMS

A01

Temperature alarm hysteresis

4°F

4°F

0°F

18°F

A02

High temperature limit alarm in pos. storing in relation to P07 18°F 18°F 0°F 90°F

A03

Low temperature limit alarm in pos. storing in relation to P07 -17°F -17°F -90°F 0°F

A04

High temperature limit alarm in neg. storing in relation to N04 18°F 18°F 0°F 90°F

A05

Low temperature limit alarm in neg. storing in relation to N04 -17°F -17°F -90°F 0°F

A06

Temperature alarm delay fron storing or defrost start

60min

60min

0min

300min

A07

Temperature alarm delay

30min

30min

0min

300min

A08

Duration of the buzzer in the alarm mode

1min

1min

0min

240min

DISPLAY

D01

Temperature unit of measurement (0 Celsius; 1 Fahrenheit)

1

1

0

1

D02

Room probe Offset

0°F

0°F

-18°F

18°F

D03

BackLight (0 on when pressing a key; 1 always on)

0

0

0

1

D04

Core probe offset

0°F

0°F

-18°F

18°F

D05

Under surface probe offset

0°F

0°F

-18°F

18°F

D06

Over surface probe offset

0°F

0°F

-18°F

18°F

DEFROST

S01

Performs defrost on quick cooling start
0 = No; 1 = Yes

0 0

0

1

S02

End-of-defrost temperature

46°F

46°F

14°F

86°F

S03

Defrost max. duration

15 min

15 min

1 min

90 min

S04

Interval between defrosts in storing (0=excluded)

0 hour

0 hour

0

18 hour

S05

Type of defrost:
0= electrical or due to compressor stop
1= hot gas
2= air

2 2

0

2

S06

Dripping time

1 min

1 min

0 min

90 min

S07

Compressor activation delay with hot gas defrost

0 sec

0 sec

0 sec

600 sec

S08

First defrost activation time from storing start (0=excluded)

0

0

0

90 min

S09

Ignores compressor protection delays in defrost

0

0

0

1

S10

Defrost type started through keyboard:
0= electrical or due to compressor stop
1= hot gas
2= air

2 0

0

2