34

Parameter Description

Default

(BCF...)

Default

(BC...)

min MAX

I.F.R.

B01

Room thermostating temperature in the first phase

-48°F

-13°F

-58°F

122°F

B02

Under surface T control start temperature

41°F 86°F

-58°F

210°F

B03

First coefficient of the control relation

0 -2

-50

50

B04

Second coefficient of the control relation

0 16

-50

50

B05

Third coefficient of the control relation

-8 -8

-50

50

B06

Under surface T initial value determining the end of the first phase

30°F 34°F

-58°F

210°F

B07

Phase two formula coefficient

99 10 0

99

B09

Under surface t min. value allowed during the third phase

32°F 30°F

-58°F

210°F

B10

End of intelligent quick cooling core temperature

46°F 38°F

-58°F

210°F

B11

Delay from the positive result of the needle test for starting the
procedure to determine the end of the first phase

60 sec

60 sec

0 sec

99 sec

B12

First phase temperature detection time

30 sec

30 sec

0 sec

99 sec

B13

First phase min. duration

6 min

6 min

0 min

99min

B16

Defrost on starting intell. QC cycle (0=no 1=yes)

0 0

0

1

B17

Inhibition temperature

194°F 176°F -58°F

210°F

B18

Room Set point in the event of automatic switch to time or
temperature mode

19°F 32°F

-58°F

210°F

B19

Max. duration possibile for intelligent QC process

999 min

150 min

1 min

999 min

B20

Under surface T safety value determining the end of the first
phase

30°F 38°F

-58°F

210°F

B21

First coefficient of the room thermostating curve (third phase)

10 -25

-90

99

B22

Second coefficient of the room thermostating curve (third
phase)

-50 -28

-90

99

B23

Storing activation at the end of intell. QC cycle
(0 = no; 1 = yes)

1 1

0

1

B24

Room thermostat Set-point in storing

36°F 36°F

-130°F

194°F

B26

Core temperature limit for the timer start

999 0 0

999

B27

Adjuster of fans speed in the third phase

99 0 0

99

B28

Cold pulse adjuster

10 0 0

99

COMMUNICATION

ADD

Device Address

1

1

1

147

SC

Serial Control :
0 = not activated
1 = print
2 = ModBus

1

1

0

2

MB1

BaudRate: 0 = 2400; 1 = 4800; 2 = 9600; 3 = 18200

2 2

0

3

MB2

Parity: 0 = no parity; 1 = odd; 2 = even

2 2

0

2

TYPE OF CYCLE

G01

Positive QC cycles only :
0 = Positive and Negative
1 = Positive only

0 0

0

1

CHANGING PARAMETERS

Press menu/esc to select the desired menu


Use the keys up and down to display

Press enter to confirm your choice.

The display shows

(only the 1st time)

Service

Esc

Service

Password 0