TAB.5

FAULT

CAUSE

REMEDY

No voltage on
Anomalous stop

No power supply
Blown fuse
Loosened connections

Restore power supply
Replace fuses
Check connection fitting

Compressor

failure

High and Low-pressure pressure-
switch on
Clicker on
Contactor failure
Compressor thermal relay on

Ask for skilled assistance
Ask for skilled assistance
Ask for skilled assistance
Ask for skilled assistance

The compressor is working but
the cabinet is not cooling

Frosted evaporator
No coolant inside the refrigerating
system
Delivery solenoid valve failure

Open the door and carry out defrost cycle
Ask for skilled assistance
Ask for skilled assistance

Evaporator fans are not working

Fan failure or short-circuit
Door micro failure

Ask for skilled assistance
Ask for skilled assistance

The cycle cannot start

Wrong cycle programming

Check time and temperature parameters

AL High Press

High Pressure Switch

Qualified technician required

AL Room Probe

Room Probe interrupted

Qualified technician required

AL Evap Probe

Evap Probe interrupted

Qualified technician required

AL Cond Probe

Cond Probe interrupted

Qualified technician required

AL Needle Probe

Needle Probe interrupted

If a probe cycle is running, the cycle is time-controlled
Qualified technician required

AL Insert Needle

Needle Probe not inserted

Check the probe inserting cone

High T Room

Room Temp above set value

If the temperature is not within the specified range, apply
to a qualified technician

Low T Room

Room Temp below set value

If the temperature is not within the specified range, apply
to a qualified technician

AL BlackOut

No power supply

When power is restored, check the max. temperature
reached inside the room

AL Door Open

QC room door open
Door micro faulty

Close the door
Qualified technician required