33

Parameter Description

Default

(BCF...)

Default

(BC...)

min MAX

CONFIGURATION

C01

Door input (0 de-activated; 1 activated)

1

1

0

1

C02

Door open polarity

0

0

0

1

C03

Door open alarm delay

2 min

2 min

0 min

60 min

C04

Activates buzzer (0 de-activated; 1 activated)

1

1

0

1

C05

Buzzer duration at the end of quick cooling cycle

10 sec

10 sec

0

600 sec

C06

Temperature difference in the first phase of needle insertion
test (0 = test excluded)

13°F 45°F 0 140°F

C07

Duration of the second phase of needle insertion test (0=test
excluded)

56 sec

56 sec

0

600 sec

C08

Activates condenser probe
0 = no probe
1 = probe

1

1

0

1

C09

Compressor stop delay due to door opening

30 sec

30 sec

0 sec

60 sec

C10

Control pressure alarm detection time

5 sec

5 sec

0 sec

60 sec

C11

High pressare digital input polarity

0

0

0

1

C12

Resistances starting SetPoint

23°F

23°F

14°F

68°F

ADJUSTMENT

R01

Compressor start/stop hysteresis 5°F

38°F

0°F

36°F

R02

Min. interval between 2 compressor starting

2 min

2 min

0 min

30 min

R03

Compressor start delay from card activation

0 sec

0 sec

0 sec

300 sec

R04

Compressor Duty-Cycle time with faulty room probe in storing

10 min

10 min

0 min

90 min

R05

Compressor ON time faulty room in pos. storing

3 min

3 min

0 min

90 min

R06

Compressor ON time with faulty room in neg. storing

8 min

8 min

0 min

90 min

R07

Needle min. temperature for starting quick cooling

158°F

158°F

32°F

194°F

R08

Compressor block temperature

194°F

194°F

32°F

212°F

R09

Compressor Protection function activation time

24 hour

24 hour

0 hour 240 hour

R10

Pulse duration

2 sec

2 sec

1 sec

10 sec

R11

Pause between pulses

8 sec

4 sec

1 sec

10 sec

R12

Number of pulses

3

3

1

20

R13

Temperature at the end of the Cooling cycle

-13°F

-13°F

-58°F

50°F

FANS

F01

Evaporator fans activation hysteresis

4°F

36°F

0°F 36°F

F02

Condenser fans activation hysteresis

4°F

36°F

0°F 36°F

F03

Evaporator fans activation SetPoint

41°F

41°F

-58°F

122°F

F04

Condenser fans activation SetPoint

59°F

59°F

-58°F

122°F

F05

Evaporator fans during defrost
0 = fans OFF; 1 = fans ON

0 0

0

1

F06

Condenser fans during defrost
0 = fans OFF; 1 = fans ON

0 0

0

1

F07

Fans stop time after defrost

1 min

1 min

0 min

30 min

F08

Condenser fans stop delay

30 sec

30 sec

0 sec

300 sec

F09

Evaporator fans control during quick cooling:
0 = fans always ON
1 = fans thermostated by evaporator temperature

0 0

0

1

F10

Evaporator fans control during storing:
0 = fans in parallel with the compressor
1 = fans thermostated by evaporator temperature

0 0

0

1

F11

Evaporator fans block temperature

158°F

158°F

32°F

194°F

PRINT

PR1

Sampling time

10 min

10 min

1 min

60 min

VENTILATION SPEED (P.W.M.)

CF1

Evaporator fan min. speed

30

20

0 100

CF2

Evaporator fan min. speed selectable in a quick cooling cycle

50

50

0 100