Tweco 7-3470 Manuel d'utilisation
General information, Supplied parts, Installation procedure
February 24, 2003 / 24 Février, 2003
1
Manual / Manuel 0-2929
Manual 0-2929
Remote Pendant Adapter Kit
Catalog # 7-3470
Installation Instructions
General Information
This kit connects a Thermal Dynamics Remote Pendant to SL60 or SL100 Torches equipped with the ATC connector.
Supplied Parts
The kit includes:
• Adapter Fitting
• Wire Assembly
• Wire Nut
• Instructions
WARNING
Disconnect primary input power to the system before starting the installation.
Shut off input gas supply and bleed down the system.
Only a qualified technician should perform this procedure.
Installation Procedure
A. Preparation
1. Disconnect the ATC male connector from the female receptacle.
2. For shielded leads only:
a. Remove the tie wrap securing the outer woven nylon leads cover to the ATC connector.
b. Slide back the insulating boot covering the leads assembly and extending partway over the ATC connec-
tor.
c. Remove the metal tie wrap securing the wire mesh leads shield to the ATC Connector. Slide the wire
mesh leads shield off the ATC Connector.
3. Disassemble the ATC male connector as follows:
a. Remove 4 screws from the shell halves.
b. Separate and remove the shell halves.
4. One shell half includes a molded knockout. Remove the plastic material from this knockout. Smooth the
edges of the knockout.
© 2002 by Thermal Dynamics Corp., Printed in USA
82 Benning Street, West Lebanon, NH 03784 USA
(603) 298-5711 • www.thermal-dynamics.com
NOTE
The following sections differ between shielded and
unshielded applications.