Rs-232c, Query control commands – Panasonic AG-DTL1 Manuel d'utilisation

Page 85

Advertising
background image

85

[STX] QCC [ETX]

[STX] CCPdata [ETX]

Parameter
data = ghmmssff

g = Blank : With a positive (+) value

– sign : With a negative (–) value

h =

0—9: Hours (12-hour system)

mm = 00—59 : Minutes
ss =

00—59 : Seconds

Queries the current CTL counter data (in 1-second
increments).

RS-232C

$

Query control commands

Data transmitted by PC

Data returned from unit in response

Description of command

[STX] QBP [ETX]

[STX] LBPm [ETX]

Parameter
m = ¢: The video signals of all the

cameras are output.

0: Camera 1
1: Camera 2
2: Camera 3
3: Camera 4
4: Camera 5
5: Camera 6
6: Camera 7
7: Camera 8
8: Camera 9
9: Camera 10
A: Camera 11
B: Camera 12
C: Camera 13
D: Camera 14
E: Camera 15
F: Camera 16

Queries the camera whose video signals are not to be
output to the VIDEO OUT connector.

[STX] QBR [ETX]

[STX] LBRm [ETX]

Parameter
m = N: Buzzer ON

F: Buzzer OFF

Queries the setting for whether the buzzer is to sound when
REC REVIEW reveals that the proper video level was not
maintained.

[STX] QCD [ETX]

[STX] CDdata [ETX]

Parameter
data = fwghmmssff

f = F: Fine

C: Coarse

w = S: Search STILL

P: Search PLAY

g = Blank : With a positive (+) value

– sign : With a negative (–) value

h =

0—9: Hours (12-hour system)

mm = 00—59 : Minutes
ss =

00—59 : Seconds

ff =

00 (fixed) : Frames

Queries the current CTL counter data.

Advertising