Terminal signal levels, External interface preparation specifications – Panasonic AG-DTL1 Manuel d'utilisation

Page 38

Advertising
background image

38

External interface preparation
specifications

O

Use devices with ratings which support the actual
operating conditions.

Example of lamp lighted by HIGH signal

(Lamp, etc.)

Power

Relay

Control signal

GND

Terminal signal levels

Terminal

Remarks

Signal level

ALARM IN
1/2

Ground input

V IH = 4.0 V to 5.0 V
V IL = 0.0 V to 0.6 V
T S 100 ms

ALARM
RESET IN

High input

V IH = 4.0 V to 5.0 V
V IL = 0.0 V to 0.6 V
T S 100 ms

T

V

IH

V

IL

T

V

IH

V

IL

REC IN

Ground input

V IH = 4.0 V to 5.0 V
V IL = 0.0 V to 0.6 V
T S 100 ms

T

V

IH

V

IL

EXT TIMER
IN

Ground input
Recording is
performed during
the V IL input (T).

V IH = 4.0 V to 5.0 V
V IL = 0.0 V to 0.6 V
T: Recording time

T

V

IH

V

IL

EXT TIMER
OUT

Ground output
Output time T is set
using the EXT
TIMER OUT item on
the menu screen
shown on P7
TERMINAL
OUTPUT SELECT.

V OL = 0.0 V to 0.6 V

V

OL

T

OPEN

OPEN

ALARM OUT

Ground output
The output format is
set using the
ALARM/SENSOR
OUT item on the
menu screen shown
on P7 TERMINAL
OUTPUT SELECT.

V OH = 11.0 V to 13.0 V
V OL = 0.0 V to 0.6 V
4.7 k

Ω pull-up resistor (+12V) output

V

OH

V

OL

Terminal

Remarks

Signal level

TIME ADJ IN

Ground input

V IH = 4.0 V to 5.0 V
V IL = 0.0 V to 0.6 V
T S 100 ms

T

V

IH

V

IL

TAPE END
OUT

Ground output
When REPEAT has
been selected as
the (TAPE END)
MODE setting on
the menu screen
shown on P5 (VTR
MODE SELECT),
output time T is 2
seconds. If a setting
other than REPEAT
is selected, the
signal will continue
to be output until
one of the function
buttons is pressed.
The signal will
continue to be
output until one of
the function buttons
is pressed also
when a setting other
than OFF has been
selected as the
LEVEL setting on
the menu screen
shown on P6 TAPE
REMAIN.

V OH = 11.0 V to 13.0 V
V OL = 0.0 V to 0.6 V
4.7 k

Ω pull-up resistor (+12V) output

T

V

OH

V

OL

WARNING/R
EC OUT

Ground output

Open drain output
V OL = 0.0 V to 1.0 V
Max. 200 mA drive enabled

T

V

OH

V

OL

Advertising