Terminal connections, Tape-end output connections, External timer input connections – Panasonic AG-DTL1 Manuel d'utilisation

Page 36

Advertising
background image

36

1 2

GND

IN

REC IN

GND TIME ADJ IN

TAPE END OUT

RESET

ALARM

EXT

TIMER

OUT

IN OUT

WARNING
/REC OUT

Terminal connections

Tape-end output connections

When the cassette tape comes to its end during
recording, the alarm device which has been installed
externally is triggered.

Alarm lamp

External
interface

1 2

GND

IN

REC IN

GND TIME ADJ IN

TAPE END OUT

RESET

ALARM

EXT

TIMER

OUT

IN OUT

WARNING
/REC OUT

External timer input connections

An external timer can be used for recording.

O

Select ON for EXT TIMER IN on the menu screen
shown on P7 TERMINAL INPUT SELECT, and set
the front panel TIMER MODE button to EXT
(external timer recording).
The unit’s power is turned off, and recording is
started by the signal from the external timer.

External timer

1 2

GND

IN

REC IN

GND TIME ADJ IN

TAPE END OUT

RESET

ALARM

EXT

TIMER

OUT

IN OUT

WARNING
/REC OUT

Auto OFF output connections and
recording output connections

The auto OFF output and recording output
connections are the same. Select between them
using ERROR WARN/REC OUT on the menu screen
shown on P7 TERMINAL OUTPUT SELECT.

Auto OFF output
When a problem has occurred in the unit, the alarm
device which has been installed externally is
triggered.
In this case, the error code appears on the display.
(See page 102.)

Recording output
When the unit is set to the recording mode, the alarm
device which has been installed externally is
triggered.

Alarm lamp

External
interface

Power OFF

Power OFF

External timer signal

Recording proceeds in the recording
mode which was set by menu screen P4
RECORDING MODE.

External timer

recording

Advertising