Rs-232c, Query control commands – Panasonic AG-DTL1 Manuel d'utilisation

Page 88

Advertising
background image

88

RS-232C

$

Query control commands

Data transmitted by PC

Data returned from unit in response

Description of command

[STX] QHJ [ETX]

[STX] HEm [ETX]

Parameter
m = E: EJECT

A: REWIND5EJECT

Queries the setting for the operation to be performed when
the EJECT button is pressed.

[STX] QHL [ETX]

[STX] HRLm [ETX]

Parameter
m = F: Recording enabled

N: Recording disabled

Queries the lock mode for operations while recording is
underway.

[STX] QHR:H [ETX]

[STX] HTRdata [ETX]

Parameter
data = hhmmss
hh = 00—23:

Hours

mm = 00—59:

Minutes

ss =

00 (fixed): Seconds

Queries the remaining tape amount.
When the amount is undetermined or the tape has been
ejected, data = FFFFFF is returned.
<Note>
This command is valid when a 120-minute tape is used and
the 3-hour recording mode has been set.

[STX] QHR:H [ETX]

[STX] HTRdata [ETX]

Parameter
data = hhmmss
hh = 00—23:

Hours

mm = 00—59:

Minutes

ss =

00 (fixed): Seconds

Queries the remaining tape amount.
When the amount is undetermined or the tape has been
ejected, data = FFFFFF is returned.
<Note>
This command is valid when a 120-minute tape is used and
the 3-hour recording mode has been set.

[STX] QHT [ETX]

[STX] HREm [ETX]

Parameter
m = B: BUZZER

E: EJECT
P: REPEAT
R: REWIND
S: STOP

Queries the unit’s operation mode that is to be established
when the tape has reached its end position during
recording.

[STX] QIC [ETX]

[STX] 1 [ETX]

Queries the product area identification code.
The unit returns “1” for a tape component.

[STX] QID [ETX]

[STX] data [ETX]

Parameter
data = AG-DTL1P

Queries the ID code of the unit.

[STX] QIP:n [ETX]

Parameter
n = 1—8: Program registration

number (PGM1—PGM8)

[STX] LIPn:data1:data2:t [ETX]

Parameter
n = 1—8: Program registration number

(PGM1—PGM8)

data1 = hhmm (start time)
data2 = hhmm (end time)

hh = 00—23: Hours (24-hour system)
mm = 00—59: Minutes

t = 0—6: Recording type (RT0—RT6)

Queries the program which combines three items—the
recording start time, recording end time and the recording
type—for recording using the unit’s internal timer.

Advertising