26

En

English

Operation

Automatic power-off
(POWER MANAGEMENT)

The plasma display is equipped with [POWER
MANAGEMENT] and [AUTO POWER OFF] functions;
when set, the function automatically switches the unit to
either standby mode or power off mode whenever a sync
signal is not detected (a warning message is displayed on
the screen before the functions operate).

Notes

÷ [POWER MANAGEMENT] settings are supported only when a

computer signal is input to INPUT 1 or INPUT 5 (PDA-5003
only), or when INPUT2 is selected.

÷ The auto-power-off function can be used only in those cases

other than the inputs used in the preceding item.

÷ Always turn off the plasma display’s main power switch when

not using the display for extended periods of time.

INPUT

MENU

SET

2/3

1

Press the MENU button to display the menu screen.

MENU

INPUT1

PICTURE

SCREEN

SETUP

OPTION

:

0

:

0

:

0

:

0

:

0

:

0

CONTRAST

:

0

BRIGHTNESS
R.LEVEL
G.LEVEL
B.LEVEL
H.ENHANCE
V.ENHANCE

PICTURE RESET

2

Use the

2/3 buttons to select [SETUP].

[When computer signal is input to INPUT1 or
INPUT5 (PDA-5003 only), or when INPUT2 is used]

: V G A

:
:

SIGNAL FORMAT

CLAMP POSITION

:

AUTO

POWER MANAGEMENT

OFF

MENU

INPUT1

PICTURE

SCREEN

SETUP

OPTION

[In all other cases]

SET

MENU

:
:

DNR

COLOR TEMP.

:

MIDDLE
MIDDLE

:
:

COLOR SYSTEM

PURECINEMA

OFF
AUTO

:
:

CTI

ON

MPEG NR

LOW

AUTO POWER OFF

DISABLE

MENU

INPUT3

PICTURE

SCREEN

SETUP

OPTION

CHANGE

EXIT

3

Press the SET button to confirm selection of the
[POWER MANAGEMENT] or [AUTO POWER OFF].
The factory default setting is [OFF/DISABLE].
Each time the button is pressed, the setting alternates
as follows:

÷ OFF/DISABLE.....

The display will continue in operating mode,
regardless of the presence/absence of an input sync
signal.

÷ POWER MANAGEMENT: ON.....

If a sync signal is not detected, a warning message is
first displayed for 8 seconds, after which the display
automatically enters the standby mode, and the ON
indicator flashes green. If a sync signal (*1) is input
again later, the plasma display automatically returns to
normal operating mode.

*1 Except when input signal is G ON SYNC or composite

SYNC.

÷ AUTO POWER OFF: ENABLE.....

If no sync signal is detected for 8 minutes or more, a
warning message will be displayed for 30 seconds,
after which the display’s power will switch to power off
mode.

4

When the setup is finished, press the MENU
button to exit the menu screen.

Note

The [POWER MANAGEMENT] and [AUTO POWER OFF]
functions must be set individually for each input (INPUT1 to

INPUT5).

To return to operating mode:

÷ To return to normal operation from the [POWER

MANAGEMENT] function’s standby mode, either operate
your computer, or press the INPUT button on the plasma
display or remote control unit.

÷ To return to normal operation from the [AUTO POWER

OFF] function’s power off condition, press the STANDBY/
ON
button on the plasma display or on the remote control
unit.

Operation

MENU

SET

2/3

INPUT

Remote control unit

Display operating
panel

3 OFF/DISABLE

ON/ENABLE

2