63 english, Specifications (cont.) – JVC D-ILA DLA-QX1G Manuel d'utilisation

Page 65

Advertising
background image

63

ENGLISH

2-3. Parameters used for the data format

The following three kinds of parameters are prepared for the control command and response data.

(1) Numeric value

Designates the 2-byte hexadecimal value with the sign as the 4-digit (byte) characters.
Designation allowable range : “8000” to “7FFF”

(2) ON/OFF

Designates the status (ON/OFF) of the projector, such as POWER and HIDE.

Character

Hex.

Meaning

“0”

30

OFF

“1”

31

ON

(3) Special parameters

Input switching parameters:

Character

Hex.

Meaning

“1”

30

VIC1

“2”

31

VIC2

“3”

33

VIC3

Operation mode parameters:

Character

Hex.

Meaning

“0000”

30h 30h 30h 30h

Stand-by mode

“0001”

30h 30h 30h 31h

Power-on mode

“0002”

30h 30h 30h 32h

Cool-down mode

“0004”

30h 30h 30h 34h

Warning mode

3. Control command table

The control commands that can be sent from the computer are as follows:

Function

Command

Asking

Kind of data

Power ON

ELSE

Numeric Value

ON/OFF

Special Data

OPERATE

U0F

HIDE

U00

Right Left rev.

U17

Keystone

U40

Input

U1A

VIC1, VIC2, VIC3

Operation mode

Z03

Stand-by, Power-on,

Cool-down, Warning

* Keystone: Numeric value can range from “FF80” to “0080”
* Operation mode: Only Asking command is possible

Specifications (Cont.)

EN59-63QX1G_f.pm6

02.3.7, 13:39

63

Advertising