Déclaration de fabricant sil (anglais), Declaration by the manufacturer – Richter NKP Series Butterfly Valves Manuel d'utilisation

Page 42

Advertising
background image

Erstellt/

Prepared by

:

CRQ/AL

am/

on

: 27.01.11

Seite/

Page

: 1

QM-Nr./

QM-No.

: 0905-40-1049_NK/4-00

Genehmigt/

Released by

: CRQ/AL

am/

on

: 27.01.11

von/

of

:

1






A Unit of IDEX Corporation

Kempen, 27.01.2011

SIL

Declaration by the Manufacturer

Functional Safety according to IEC 61508

We declare, that the devices

NK, NKS, NKL

are suitable for use in a safety related application, if the safety instructions and the following

parameters are observed:

Device Type:

A

Proof Test Interval:

≤ 1 year

HFT:

0 (single channel usage)

λ

SU

:

231 FIT

λ

SD

:

26 FIT

λ

DU

:

195 FIT

λ

DD

:

62 FIT

SFF:

62,1 %

PFD

Avg

:

8,54 10

-4

(for T

Proof

= 1 year)

MTBF:

222 years

Safety Integrity Level:

SIL 2

The specified values are valid only for the valve. Accessories such as an actuator, solenoid

valves, limit switches etc. are not included.

______________________________

______________________________

Gregor Kleining

Alexander Linges

Dir. Research & Development

Quality Manager

Advertising