Napoleon Fireplaces Dream - BGD90 Manuel d'utilisation

Page 53

Advertising
background image

53

W415-0826 / C / 07.11.11

SYMPTOM

PROBLEM

TEST SOLUTION

Pilot goes out
while standing:
Main burner is in
“OFF” position.

Gas piping is undersized.

-

Turn on all gas appliances and see if pilot fl ame
fl utters, diminishes or extinguishes, especially
when main burner ignites. Monitor appliance supply
working pressure.

-

Check if supply piping size is to code. Correct all
undersized piping.

Remote wall
switch is in “OFF”
position; main
burner comes on
when gas knob
is turned to “ON”
position.

Wall switch is mounted
upside down.

-

Reverse.

Remote wall switch is
grounding.

-

Replace.

Remote wall switch wire
is grounding.

-

Check for ground (short); repair ground or replace
wire.

Faulty valve.

-

Replace.

42.2_3

Advertising