SYMPTOM

PROBLEM

TEST SOLUTION

Main burner goes

out; pilot stays on.

Pilot fl ame is not large

enough or not engulfi ng

the thermopile.

-

Turn up the pilot fl ame.

-

Replace pilot assembly.

Thermopile shorting.

-

Clean thermopile connection to the valve. Reconnect.

-

Replace thermopile / valve.

Remote wall switch wire

is too long; too much

resistance in the system.

-

Shorten wire to connect length or wire gauge.

Faulty thermostat or

switch.

-

Replace.

Main burner goes

out; pilot goes

out.

Refer to “MAIN BURNER

GOES OUT; PILOT

STAYS ON”
Vent is blocked

-

Check for vent blockage.

Vent is re-circulating

-

Check joint seals and installation

Flexible vent has become

disconnected from fi replace.

-

Re-attach to fi replace.

-

Cap was not replaced.

Pilot goes out

when the gas

knob is released.

The gas valve
has an interlock
device which
will not allow
the pilot burner
to be lit until the
thermocouple
has cooled. Allow
approximately 60
seconds for the
thermocouple to
cool.

System is not correctly

purged.

-

Purge the gas line.

Out of propane gas.

-

Fill the tank.

Pilot fl ame is not large

enough.

-

Turn up the pilot fl ame.

Pilot fl ame is not engulfi ng

the thermocouple

-

Gently twist the pilot head to improve the fl ame

pattern around the thermocouple.

Thermocouple shorting /

faulty.

-

Loosen and tighten thermocouple.

-

Clean thermocouple and valve connection.

-

Replace thermocouple.

-

Replace valve.

Faulty valve.

-

Replace.

Pilot burning;

no gas to main

burner; gas

knob is on ‘HI’;

wall switch /

thermostat is on.

Thermostat or switch is

defective

-

Connect a jumper wire across the wall switch terminals;

if main burner lights, replace switch / thermostat.

Wall switch wiring is

defective.

-

Disconnect the switch wires & connect a jumper

wire across terminals 1 & 3; if the main burner lights,

check the wires for defects and / or replace wires.

Main burner orifi ce is plugged.

-

Remove stoppage in orifi ce.

Faulty valve.

-

Replace.

Pilot will not light.

No spark at pilot burner.

-

Check if pilot can be lit by a match.

-

Check that the wire is connected to the push button igniter.

-

Check if the push button igniter needs tightening.

-

Replace the wire if the wire insulation is broken or frayed.

-

Replace the electrode if the ceramic insulator is cracked or broken.

-

Replace the push button ignitor

Out of propane gas.

-

Fill the tank.

Spark gap is incorrect.

-

Spark gap should be 0.150” to 0.175” (5/32” to 11/64” approx.)

from the electrode tip and the pilot burner. To ensure proper

electrode location, tighten securing nut (fi nger tight plus 1/4 turn).

No gas at the pilot burner.

-

Check that the manual valve is turned on.

-

Check the pilot orifi ce for blockage.

-

Replace the valve.

-

Call the gas distributor.