background image

26

W415-0826 / B / 07.11.11

IMPORTANT:

The

requires a minimum inside enclosure height of 96” measured from the bottom of the appliance.

For temperature requirements, this area must be left unobstructed.

It is recommended that the enclosure be ventilated at the top and bottom to circulate the hot air with 2, 40”
square openings.

* See Venting Section

** Within the appliance enclosure a 9” clearance between the vertical vent run and the combustible materials
on the front facing of the enclosure is required. Similarly, a 5” clearance to combustible materials from the top
of the horizontal vent run is required. All other clearances within the enclosure, including where the vent pipe
exits the enclosure are subject to 2” for horizontal and 1” for vertical.

5.2 MINIMUM ENCLOSURE CLEARANCES

!

WARNING

RISK OF FIRE!

THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS

SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT COVER

THE APPLIANCE OPENING.

2”

2”

96”

46 1/2”

9”**

86 1/2”

MINIMUM

PLUS

RISE*

COMBUSTIBLE

NON-COMBUSTIBLE

BRICK

COMBUSTIBLE

NON-

COMBUSTIBLE

0” IF NON-
COMBUSTIBLE FINISH-
ING IS USED SUCH AS
BRICK AND STONE

TOP OF

FIREPLACE

TOP OF

FIREPLACE

OPENING

5”**

1”