4.2 USING FLEXIBLE VENT COMPONENTS

For safe and proper operation of the appliance, follow the venting
instructions exactly.
All inner fl ex pipe and outer fl ex pipe joints may be sealed using high
temperature sealant W573-0002 (not supplied) or the high temperature
sealant W573-0007 Mill Pac (not supplied). However, the high temperature
sealant W573-0007 Mill Pac (not supplied) must be used on the joint
connecting the inner fl ex pipe and the exhaust fl ue collar.
Use only approved fl exible vent pipe kits marked:

“Wolf Steel Approved Venting” as identifi ed
by the stamp only on the outer fl ex pipe.

22.1

ELBOW

SPACERS

DO NOT ALLOW THE INNER FLEX PIPE TO BUNCH UP ON HORIZONTAL OR VERTICAL RUNS AND ELBOWS.

KEEP IT PULLED TIGHT.

SPACERS ARE ATTACHED TO THE INNER FLEX PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AN EVEN
AIR GAP TO THE OUTER FLEX PIPE. THIS GAP IS REQUIRED FOR SAFE OPERATION. A SPACER IS REQUIRED

AT THE START, MIDDLE AND END OF EACH ELBOW TO ENSURE THIS GAP IS MAINTAINED. THESE SPACERS

MUST NOT BE REMOVED.

!

WARNING

4.2.1 HORIZONTAL AIR TERMINAL INSTALLATION

A.

Stretch the inner fl ex pipe to the required length
taking into account the additional length needed for
the fi nished wall surface. Apply a heavy bead of the
high temperature sealant W573-0007 Mill Pac (not
supplied) to the inner sleeve of the air terminal. Slip
the vent pipe a minimum of 2” over the inner sleeve
of the air terminal and secure with 6 #8 screws.

B.

Using the outer fl ex pipe, slide over the outer
combustion air sleeve of the air terminal and secure
with 6 #8 screws. Seal using high temperature
sealant W573-0002 (not supplied).

C.

Insert the vent pipes through the fi restop
maintaining the required clearance to
combustibles. Holding the air terminal (lettering
in an upright, readable position), secure to the
exterior wall and make weather tight by sealing
with caulking (not supplied).

D.

If more vent pipe needs to be used to reach
the fi replace, couple them together as
illustrated. The vent system must be supported
approximately every 3 feet for both vertical and
horizontal runs. Use noncombustible strapping to maintain the minimum 1” clearance to combustibles.

The air terminal mounting plate may be recessed into the exterior wall
or siding no greater than the depth of its return fl ange.

23.4A

HI-TEMP

SEALANT

#8 X 1/2” SELF DRILLING

SCREWS & WASHERS

INNER COUPLER

OUTER COUPLER

OUTER

FLEX PIPE

INNER
FLEX PIPE

OUTER

FLEX PIPE

CAULKING

SCREWS

#10x2"

PIPE

OUTER FLEX

SEALANT

2" OVERLAP

HI-TEMP

INNER FLEX