Warning, 0 trouble shooting – Napoleon Fireplaces Dream - BGD90 Manuel d'utilisation

Page 51

Advertising
background image

51

W415-0826 / C / 07.11.11

!

WARNING

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT,

WITH THE GLASS DOOR OPEN OR REMOVED.

TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.

APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.

DO NOT USE ABRASIVE CLEANERS.

SYMPTOM

PROBLEM

TEST SOLUTION

Main burner

fl ame is a

blue, lazy,

transparent

fl ame.

Blockage in vent.

-

Remove blockage. In really cold conditions, ice buildup

may occur on the terminal and should be removed as

required. To minimize this from happening again, it is

recommended that the vent lengths that pass through

unheated spaces (attics, garages, crawl spaces) be

wrapped with an insulated mylar sleeve. Prevent sleeve

from sagging. Contact your local authorized dealer for

more information.

Incorrect installation.

-

Refer to “VENTING” section to ensure correct location of

storm collars.

Flames are

consistently

too large or

too small.

Carboning

occurs.

Unit is over-fi red or

underfi red.

-

Check pressure readings:
Inlet pressure

can be checked by turning screw (A)

counter-clockwise 2 or 3 turns and then placing pressure

gauge tubing over the test point. Gauge should read

7” (minimum 4.5”) water column for natural gas or 13”

(minimum 11”) water column for propane. Check that

main burner is operating on ‘HI’.
Outlet pressure

can be checked the same as above

using screw (B). Gauge should read 3.5” water column

for natural gas or 10” water column for propane. Check

that main burner is operating on ‘HI’.
AFTER TAKING PRESSURE READINGS, BE SURE
TO TURN SCREWS CLOCKWISE FIRMLY TO
RESEAL. DO NOT OVER TORQUE.

Leak test with a soap and water solution.

Carbon

is being

deposited on

glass, burner

media or

combustion

chamber

surfaces.

Air shutter has become

blocked.

-

Ensure air shutter opening is free of lint or other

obstructions.

Flame is impinging on

the burner media or

combustion chamber.

-

Check that the burner media is correctly positioned.

-

Open air shutter to increase the primary air.

-

Check the input rate: check the manifold pressure and

orifi ce size as specifi ed by the rating plate values.

-

Check that the door gasketing is not broken or missing

and that the seal is tight.

-

Check that both vent liners are free of holes and well

sealed at all joints.

-

Check that minimum rise per foot has been adhered to

for any horizontal venting.

White / grey

fi lm forms.

Sulphur from fuel is

being deposited on

glass, burner media or

combustion chamber

surfaces.

-

Clean the glass with a recommended gas fi replace glass

cleaner. DO NOT CLEAN GLASS WHEN HOT.

-

If deposits are not cleaned off regularly, the glass may

become permanently marked.

Exhaust

fumes smelled

in room,

headaches.

Fireplace is spilling.

-

Ensure exhaust bracket gasket seal.

-

Check door seal.

-

Check for exhaust blockage.

-

Check that venting is installed correctly.

-

Room is in negative pressure; increase fresh air supply.

42.2B

A

B

14.0 TROUBLE

SHOOTING