C. 4" (102mm) Oval In-The-Wall (all parts purchase locally)

1. Type B-1 oval pipe or B-W vent pipe

2. Type B-1 oval elbows or B-W oval elbows

3. Single story type B-1 or (B-W) gas vents require a baseplate and

one pair of ceiling plate spacers.

4. Multi-story type B-1 or (B-W) gas vents require a baseplate, one

pair of ceiling plate spacers at the first floor ceiling and one pair

of fire stop spacers at each successive ceiling level.

Stud space around gas vents must be free of obstructions and building

paper.

4” ROUND

VENT

ENCLOSURE

ADAPTER

BASEPLATE

WALL

SIDE

FRONT

A.

4” B-1 OVAL

BRACKET

BASEPLATE

B.

4” B-1 OVAL

4” B-1 OVAL

SPACER

BASEPLATE

BASEPLATE

C.

SPACER

C.

4” 45 DEG.

OVAL ELBOWS

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment or

accessories and repair and servicing of equipment shall be performed

only by a qualified agency. The term "qualified agency" means any

individual, firm, corporation or company which either in person or through

a representative is engaged in and is responsible for (a) the installation

or replacement of gas piping or (b) the connection, installation, repair or

servicing of equipment, who is experienced in such work, familiar with

all precautions required and has complied with all the requirements of

the authority having jurisdiction.
The installation must conform with local codes or, in the absence of local

codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54* Natural

and Propane Installation Code, CSA B149.1.

*Available from the American National Standards Institute, Inc., 11 West 42nd St., New

York, N.Y. 10036.

Clearances

1. In selecting a location for installation, it is necessary to provide adequate

accessibility clearances for servicing and proper installation.

2. The FAW-40 can be attached to the wall or recessed into the wall up

to 9 1/2 inches (24.1cm) in depth.

Note: Do not place combustible

header or material on top of unit when installed in wall.

Maintain 3/4" minimum spacing above heater.

3. The wall in which the furnace is recessed has (0) zero (0mm) clearance

to the furnace sides.

4. When using side discharge registers, SOR-1 or SOK-1, the furnace

cannot be recessed into the wall.

5. Clearance to sidewall or combustible material is 4 inches (10.2cm).

6. Ceiling clearance is 4 inches (10.2cm).

7. Floor and rear wall clearance is (0) zero inches (0mm).

8. Clearance of 18 inches (46cm) is required to adjacent wall or

combustible material when flush mounted SOR-1, side outlet register

is used.

Before Installing Consider The Following Venting

1. A chimney for residential-type or low-heat gas utilization equipment

shall extend at least 3 feet (914mm) above the highest point where it

passes through a roof of a building and at least 2 feet (610mm) higher

than any portion of building within a horizontal distance of 10 feet

(3m).

2. This furnace must not be connected to a chimney flue serving a

separate solid-fuel burning appliance.

3. Uninsulated Single-Wall Metal Pipe shall not be used outdoors

in cold climates for venting gas utilization equipment.

4. Attention! This Fan Type Vented Wall Furnace is equipped with a

vent safety switch. In the event of spillage of flue products due to

improper venting the vent safety switch will open, which results in

the main burners to "shut off".

Model No. FAW-40 may be vented as shown in Figure 4. The vent cap

termination must be at least 12 feet (3.7m) above the floor and must

exhaust to the outdoors.. Clearance to combustible construction is held

by the fixed spacers at 1 inch (25mm) with B-1 or (B-W) vent pipe.

Installation must conform to local codes.

A. 4" (102mm) Round (all parts purchase locally except Item 2)

1. Type B-1 round pipe

2. Part No. DV-648, 4" (102mm) oval-to-round flue adapter kit (see

accessories)

3. Single story type B-1 gas vents require a baseplate and one pair

of ceiling plate spacers.

4. Multi-story type B-1 gas vents require a baseplate, one pair of

ceiling plate spacers at the first floor ceiling and one pair of fire

stop spacers at each successive ceiling level.

B. 4" (102mm) Oval (all parts purchase locally)

1. Type B-1 oval pipe or B-W vent pipe

2. Single story type B-1 or (B-W) gas vents require a baseplate and

one pair of ceiling plate spacers.

3. Multi-story type B-1 or (B-W) gas vents require a baseplate, one

pair of ceiling plate spacers at the first floor ceiling and one pair

of fire stop spacers at each successive ceiling level.

Figure 4

Advertising
Ce manuel est liée aux produits suivants: