This is a heating appliance – Empire Products FAW-40-1SPP Manuel d'utilisation

Page 2

Advertising
background image

12427-4-0306

Page 2

The base referred to above does not mean the fire-proof base as used

on wood stoves. The protection is for rugs that are extremely thick and

light colored tile.
Installation in Residential Garages

Gas utilization equipment in residential garages shall be installed so

that all burners and burner ignition devices are located not less than 18"

(457mm) above the floor.
Such equipment shall be located, or protected, so it is not subject to

physical damage by a moving vehicle.
Specifications

Introduction

Always consult your local Building Department regarding regulations,

codes or ordinances which apply to the installation of a vented wall

furnace.
Instructions to Installer

1. Installer must leave instruction manual with owner after

installation.

2. Installer must have owner fill out and mail warranty card supplied

with furnace.

3. Installer should show owner how to start and operate furnace and

thermostat.

Warning:

Any change to this furnace or its control can be dangerous. This

is a heating appliance and any panel, door or guard removed

for servicing an appliance must be replaced prior to operating

the appliance.

General Information

This series is design certified in accordance with American National

Standard / CSA Standard Z21.86 and CSA 2.32 by the Canadian Standards

Association, as a Fan Type Vented Wall Furnace and must be installed

according to these instructions.
Any alteration of the original design, installed other than as shown

in these instructions or use with a type of gas not shown on the

rating plate is the responsibility of the person and company making

the change.
Important

All correspondence should refer to complete Model No., Serial No. and

type of gas.
Notice: During initial firing of this unit, its paint will bake out and smoke

will occur. To prevent triggering of smoke alarms, ventilate the room in

which the unit is installed.
Installation on Rugs and Tile

If this appliance is installed directly on carpeting, tile or other combustible

material other than wood flooring the appliance shall be installed on a metal

or wood panel extending the full width and depth of the appliance.

the flow of combustion and ventilation air.

• DO keep the appliance area clear and free from combustible

material, gasoline and other flammable vapors and liquids.

• DO examine venting system periodically and replace damaged

parts.

• DO make a periodic visual check of pilot and burners. Clean

and replace damaged parts.

• CAUTION: Pilot hole cover must be kept tightly closed during

operation.

• DO NOT use this heater if any part has been under water.

Immediately call a qualified service technician to inspect the

heater and to replace any part of the control system and any

gas control which has been under water.

• This furnace must not be connected to a chimney flue serving

a separate solid-fuel burning appliance.

IMPORTANT: This furnace has a washable permanent type

filter in the door which should be cleaned at least once per

year before the heating season. For dirty or high use areas

more frequent cleaning is required.

Due to high temperatures the appliance should be located out

of traffic and away from furniture and draperies.

• Children and adults should be alerted to the hazards of high

surface temperatures and should stay away to avoid burns or

clothing ignition.

• Young children should be carefully supervised when they are

in the same room as the appliance.

• Clothing or other flammable material should not be placed on

or near the appliance.

• Any safety screen or guard removed for servicing an appliance

must be replaced prior to operating the appliance.

• Keep burner and control compartment clean.
• Installation and repair should be done by a QUALIFIED SER-

VICE PERSON. The appliance should be inspected before

use and at least annually by a qualified service person. More

frequent cleaning may be required due to excessive lint from

carpeting, bedding materials, etc. It is imperative that control

compartments, burners and circulating air passageways of the

appliance be kept clean.

• DO NOT put anything around the furnace that will obstruct

THIS IS A HEATING APPLIANCE

DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANELS INSTALLED

.

Model

FAW-40SPP

FAW-40IP

Input BTU/HR (KW/H)

40,000 (11.7)

40,000 (11.7)

Height

72 1/2" (84.1mm) 72 1/2" (184.1mm)

Width

14 1/8" (35.9mm)

14 1/8" (35.9mm)

Depth

10 3/8" (26.4mm)

10 3/8" (26.4mm)

Gas Inlet Pipe

1/2" (12.7mm)

1/2" (12.7mm)

Vent Collar Type B Oval

4" (101mm)

4" (101mm)

CFM

275

275

Accessories
Register, side outlet, fixed register

SOR-1

Side outlet, 10" (254mm)

maximum extension, fixed register

SOK-1

Rear outlet, 10" (254mm)

maximum extension, adjustable register

ROK-1

Vent enclosure, 24" (609mm)

[for rooms up to 96 1/2" 2451mm) in height]

FVE-24

Vent enclosure, 34" (86cm)

[for rooms up to 106 1/2" (2705mm) in height]

FVE-34

Vent enclosure, 46" (1168mm)

[for rooms up to 118 1/2" (3009mm) in height]

FVE-46

Oval-to-Round flue adapter kit 4" (102mm)

DV-648

Advertising
Ce manuel est liée aux produits suivants: