Sequence of operation – Empire Products FAW-40-1SPP Manuel d'utilisation

Page 13

Advertising
background image

12427-4-0306

Page 13

START

System Check

Trial for

Ignition

Main Burner

Operation

END


Pilot Valve Opens

Ignitor Powered

Flame Signal

Detected

Thermostat

Calls for Heat


Ignitor OFF

Main Valve Opens

Internal Check

OK

Pilot Light and Flame is

Sensed During Trial For

Ignition (1)

Apply 24 VAC

To Appliance

Main Pilot Valves

Close

Thermostat Call for Heat

Ends

Flame Signal

Lost?


Pilot Valve Ignition OFF

Wait for Flame Signal to

Disappear


Pilot Valve Closes

Ignition OFF

Main Pilot

Valves Close

Flame Lost More

Than 5 Times in

One Call for Heat

5 Minute Retry Delay

3 Second Flame Recycle

Delay

YES

NO

NO

YES

NO

YES

YES

NO

YES

NO

(1) Ignitor will turn OFF about 30 seconds into the trial for ignition if the pilot flame has not lit. It will turn back ON for the final 30 seconds

of the 90 second trial for ignition. The pilot valve will be energized during the entire trial for ignition. This is normal operation for this gas

ignition system.