Tweco 7-3457 Manuel d'utilisation

General information, Supplied parts, Assembly

Advertising
background image

Manual / Manuel 0-2891

1

June 16, 2003 / 16 Juin, 2003

Manual 0-2891

RPT Adapter Kits

Catalog # 7-3454, 7-3457

Installation Instructions

General Information

These Replacement Torch Adapter Kits connect the Thermal Dynamics SL60 and SL100 Torch Leads with O2B fit-
tings, or ATC Adapter Kit No. 7-5207, to the following equipment:

• Kit No. 7-3454: Hypertherm* powermax* 600, 800, 900; Max* 42, 43, 40cs

• Kit No. 7-3457: Miller* Spectrum* 650, 701, 2050

Supplied Parts

The kits include:

• Adapter Assembly

• Large Insulating Sleeve

• Small Insulating Sleeve

• Bushing (used for 60-amp torch leads only)

• Instructions

Assembly

© 2002 Thermal Dynamics Corp., Printed in USA . *

Hypertherm, powermax, and Max are registered trademarks of Hypertherm, Inc.

Miller

and

Spectrum are registered trademarks of Miller Electric Co., Inc.

82 Benning Street, West Lebanon, NH 03784 USA

(603) 298-5711 • www.thermal-dynamics.com

WARNING

Disconnect primary power to the
system before disassembling the
torch or torch leads.

CAUTION

The Adapter includes a fender washer or protective end cap, held in place by a
screw. Leave the washer and screw in place until the RPT Adapter Kit is com-
pletely connected to the ATC Adapter Kit.

Connect the RPT Adapter Kit as follows:

1. Refer to the illustration. Remove 4 screws from the shell halves.

2. Separate the shell halves at the large end. Pull the shell halves away from each

other. Twist them out of the connecting ring to remove them from the assembly.

3. Cut the plastic tie wrap off the sleeved wire on the ATC adapter or torch leads.

Remove the sleeve. Disconnect the mating connectors from each other.

4. Cut the ring tongue connector off the sleeved wire on the ATC adapter or torch

leads. Strip approximately 1/4 inch / 6 mm of insulation from the end of the wire.