Tweco 7-3465 Manuel d'utilisation

Page 3

Advertising
background image

June1, 2004 / 1 Juin, 2004

3

Manual / Manuel 0-4646

B. Installation

For All Installations:

1. Refer to the following illustration. Securely connect the two Control Wire Connectors provided in this kit to the

torch control terminals on the Power Supply torch connection panel.

2. For Hand Torch or ATC Adapter Installations only:

Re - connect the two torch leads or adapter kit mating connectors disconnected previously. Slide the insulating
sleeve removed previously onto these two leads. Ensure that the sleeve covers the mating connectors com-
pletely. Secure the sleeve in place with a tie wrap provided in this kit.

3. Thread the smaller end of the gas fitting from this adapter kit onto the power supply torch connector. Tighten

securely. Do not use sealant.

4. Connect the negative / plasma lead fitting (on the torch leads or ATC Adapter) to the gas fitting previously

installed on the Power Supply. Tighten securely. Do not use sealant.

Torch Leads

Assembly

ATC Adapter Kit

Through-Hole

Protector

Securing Nut

Through-Hole

Protector Dome Nut

Through-Hole

Protector Assembly

Torch Leads

or

ATC Adapter Kit Leads

Torch Adapter

Connection Cover

Torch Control

Terminals

Control Wire

Connectors (2)

Art # A-03942

Mounting Hardware

Or

Torch

Connector

Adapter

Fitting

Insulating

Sleeve

Pilot Lead

Hex Nut

Flare Fitting

Torch

Control

Wires

Torch Connection Opening
in Power Supply Front Panel

Ring

Terminal

Small

Adapter Fitting

Small

Connection

Fitting

Negative/Plasma

Lead Fitting

Tie Wrap

Bottom Flange

Connections for Hand Torch Leads with O2B Connector, or for ATC Adapter (for Hand or Machine Torch)