SECTION 1 - CONSIGNES DE SÉCURITÉ
1-2
– JLG Sizzor –
3122113
1.3
RISQUE D’ÉLECTROCUTION
DANGER
NE PAS MANOEUVRER LA MACHINE NI DÉPLACER DU PERSON-
NEL DANS UNE ZONE INTERDITE. SUPPOSER QUE TOUTES LES
PIÈCES ET CÂBLES ÉLECTRIQUES SONT SOUS TENSION À
MOINS D’ÊTRE SÛR QUE L’ALIMENTATION A ÉTÉ COUPÉE.
NOTE : MAINTENIR UNE D.M.S. PAR RAPPORT À
TOUTES LES AUTRES LIGNES ET PIÈCES SOUS
TENSION, AINSI QUE CELLES REPRÉSENTÉES.
D.M.S. = DISTANCE MINIMALE DE SÉCURITÉ
(VOIR LE TABLEAU CI-DESSOUS)
MAINTENIR UNE DISTANCE MINIMALE DE SÉCURITÉ
PAR RAPPORT AUX LIGNES ET AUX APPAREILS ÉLEC-
TRIQUES. LAISSER UN JEU POUR LE BALANCEMENT
O U L E F L É C H I S S E M E N T D E L A N A C E L L E O U
L’OSC ILLATION DES LI GNES ÉLECTRIQUES . LA
MACHINE N’EST PAS ISOLÉE EN CAS DE CONTACT OU
DE PROXIMITÉ AVEC UN CONDUCTEUR SOUS TEN-
SION.
MAINTENIR UNE DISTANCE D’AU MOINS 3 MÈTRES (10
FEET) ENTRE LA MACHINE OU SA CHARGE ET TOUT
APPAREIL OU LIGNE ÉLECTRIQUE PORTEUR DE 50 000
VOLTS OU MOINS. AJOUTER 0,3 M (1 FT) POUR TOUTE
TENSION SUPPLÉMENTAIRE DE 30 000 VOLTS OU
MOINS.
Tableau 1-1.
Distances minimales de sécurité (D.M.S.) par rapport aux
lignes ou pièces sous tension (exposées ou isolées)
PLAGE DE TENSION
(phase à phase)
DISTANCE MINIMALE DE SÉCURITÉ
Mètres (Feet)
0 à 300 V
ÉVITER TOUT CONTACT
Plus de 300 V à 50 KV
3 (10)
Plus de 50 KV à 200 KV
5 (15)
Plus de 200 KV à 350 KV
6 (20)
Plus de 350 KV à 500 KV
8 (25)
Plus de 500 KV à 750 KV
11 (35)
Plus de 750 KV à 1000 KV
14 (45)