United States Stove Company 3000 (L) Manuel d'utilisation

Page 7

Advertising
background image

Ussc

7

INSTALLATION

SAFETY NOTICE
• IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO

REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS.

• THIS STOVE IS NOT APPROVED FOR INSTALLATION IN A MANUFACTURED OR MOBILE

HOME.

• CONSULT YOUR MUNICIPAL BUILDING DEPARTMENT OR FIRE OFFICIALS ABOUT

PERMITS, RESTRICTIONS AND INSTALLATIONS REQUIREMENTS IN YOUR AREA.

• USE SMOKE DETECTORS IN THE ROOM WHERE YOUR STOVE IS INSTALLED.
• KEEP FURNITURE AND DRAPES WELL AWAY FROM THE STOVE.
• NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL

LIGHTER FLUID, OR SIMILAR LIQUIDS TO START OR “FRESHEN UP” A FIRE IN THIS

HEATER. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IT IS IN

USE.

• IN THE EVENT OF A CHIMNEY FIRE, PUSH THE AIR CONTROL FULL CLOSED TO

DEPRIVE THE FIRE OF OXYGEN. CALL THE FIRE DEPARTMENT.

• DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
• A SOURCE OF FRESH AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED

WHEN REQUIRED.

POSITIONING THE STOVE

It is very important to position the wood stove as close as possible to the chimney, and in an area

that will favor the most efficient heat distribution possible throughout the house. The stove must

therefore be installed in the room where the most time is spent, and in the most spacious room

possible. Recall that wood stoves produce radiating heat, the heat we feel when we are close to a

wood stove. A wood stove also functions by convection, that is through the displacement of hot air

accelerated upwards and its replacement with cooler air. If necessary, the hot air distribution from

the stove may be facilitated by the installation of a blower.

The wood stove must not be hooked up to a hot air distribution system since an excessive

accumulation of heat may occur.
A wood stove must never be installed in a hallway or near a staircase, since it may block the

way in case of fire or fail to respect required clearances.