Troubleshooting and repair, Retest after repair – Lincoln Electric VANTAGE SVM178-B Manuel d'utilisation
Page 256
Advertising

TROUBLESHOOTING AND REPAIR
F-68
F-68
VANTAGE® 500
RETEST AFTER REPAIR
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine’s electrical characteristics. OR
• If you repair or replace any electrical components.
ENGINE RPM
Mode
No Load RPM
Load RPM
Low Idle
1400 - 1450
NA
High Idle
1890 - 1910
1750 - 1890
WELDER DC (STICK) OUTPUT
Mode Selector
Open Circuit
Switch
Fine Control
Voltage
Load Volts
Load Amps
30-575 Setting
Maximum
55 - 60
39.5 - 42.0
565 - 585
WELDER CV (WIRE) OUTPUT
Mode Selector
Open Circuit
Switch
Fine Control
Voltage
Load Volts
Load Amps
CV - Wire
Maximum
55 - 60
39 - 42
520 - 535
CV - Wire
Maximum
NA
48 - 49
20
CV - Wire
Minimum
55 - 60
13 - 14
20