Theory of operation, Engine rotor stator, Weld control board – Lincoln Electric VANTAGE SVM178-B Manuel d'utilisation

Page 183

Advertising
background image

THEORY OF OPERATION

E-3

E-3

VANTAGE® 500

FIGURE E.3 - WELD WINDINGS, RECTIFIER, POWER MODULES AND FEEDBACK

WELD WINDINGS, RECTIFIER,
POWER MODULES AND
FEEDBACK

The three-phase stator weld windings are connected to a
three-phase rectifier bridge. The resultant DC voltage is
applied to four paralleled capacitors incorporated within each
of the two power modules. There are two capacitors in each
module. These capacitors function as filters and also as
power supplies for the IGBTs. See IGBT Operation in this
section. The IGBTs act as high-speed switches operating at
20KHZ. These devices are switched on and off by the Weld
Control PC board through pulse width modulation circuitry.
See Pulse Width Modulation discussion in this section.

This chopped" DC output is applied through choke coils and
a shunt to the welding output terminals. The choke functions
as a current filter, and it helps to balance the outputs of the
two power modules. Free-wheeling diodes are incorporated
in the power modules to provide a current path for the stored
energy in the choke when the IGBTs are turned off. See the
Chopper Technology discussion in this section.

Output voltage feedback from the output terminals and current
feedback from the shunt is fed to the Weld Control PC board
as a means of controlling the output.

NOTE: Unshaded areas of Block Logic

Diagram are the subject of discussion

ENGINE

ROTOR

STATOR

AUXILIARY

WINDINGS

W

E

L

D

W

I

N

D

I

G

MECHANICAL

ROTATION

ALTERNATOR

OUTPUT

CONTROL

MODE

SELECT

SWITCH

SLIP

RINGS

ARC

CONTROL

WELD

CONTROL

BOARD

VOLTMETER

AMMETER

42 VAC and 120VAC

to 14 Pin Amphenol

for Wire Feeder

(No 120 VAC on EURO Models)

THREE-PHASE

RECTIFIER

+

+

+

+

__

__

TO WELD

CONTROL

BOARD

_

_

START

BUTTON

+

BATTERY

ON

STARTER

+12 VDC

RUN

ENGINE

SENSORS

OIL

PRESSURE

WATER

TEMP.

PERIPHERAL

PCB

PULL

COIL

PCB

+12 VDC

RUN

FUEL

SOLENOID

PULL

HOLD

FLASHING

IDLER

SOLENOID

LOW IDLER SIGNAL (TO SUPPLY PULL VOLTS)

HOLD VOLTS FROM CONTROL PCB

25

(COLD)

120 VAC

RECEPTACLES

(Not on EURO Machnes)

AC RECEPTACLES

Various combinations of

1Ø and 3Ø Outputs.

See Techincal Specs.

IGBT

IGBT

CHOKE

R4-50

2-POWER MODULES

SHUNT

TO

CONTROL

PCB

AUX. POWER

USE SENSING

+12VDC

RUN

80 VDC

PWM

SIGNAL

PWM

SIGNAL

120V

AC

160VDC

120VAC

PULL

RUN/STOP

SWITCH

* On some codes the Peripheral Board, Pull Coil Board, Idler Solenoid & Fuel Solenoid are

replaced by an Electronic Governor Control module and components. See Wiring Diagram.

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Advertising