Figure f.14, And figure f.14, Troubleshooting and repair – Lincoln Electric VANTAGE SVM178-B Manuel d'utilisation

Page 227: Output rectifier bridge test (continued)

Advertising
background image

WELD WINDING

LEAD CONNECTIONS

W1

W6

W3

W2

W5

W4

FIGURE F.14 – DIODE LEAD REMOVAL

OUTPUT RECTIFIER BRIDGE TEST(CONTINUED)

9. Using the 7/16” wrench, remove the stator leads

from the three AC terminals. Label leads for
reassembly. Note leads and AC terminals place-
ment for reassembly. See Figure F.15.

10. Electronically isolate the 3 AC terminals leads by

carefully bending them out into “free air”

11. With an ohmmeter or diode tester, check each of

the 3 AC terminals to their respective heat sinks.

12. Reverse the tester leads and check the diodes

again. Diodes should have a low resistance in one
polarity and very high resistance in the opposite
polarity. See diode test Table F.2.

* One open diode will not be detected.

13. Replace rectifier bridge if any “shorted” or “open”

diode as tests indicate.

14. Replace the AC terminals and stator leads.

Assemble the washers and nuts.

15. Replace the lower front panel and output leads.

16. Replace the upper control panel and secure.

17. Replace the front left and right case sides.

* One open diode will not be detected.

TROUBLESHOOTING AND REPAIR

F-39

F-39

VANTAGE® 500

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Advertising