Figure f11, Troubleshooting and repair, Back of control panel typical 1ø auxiliary machine – Lincoln Electric VANTAGE SVM178-B Manuel d'utilisation
Page 223: Back of control panel typical 3ø auxiliary machine, Stator voltage test (continued)
Advertising

32
32A
42A
42B
236A
CB6
CB5
CB3
CB2
J13
CB1
3C
6D
3D
6
4
3
5C
5E
6B
6C
3B
4A
GND-L
STATOR LEADS
3A
GND-C
GND-D
6E
5B
J12
J10
GND-E
J11
238B
Back of Control Panel
Typical 3Ø Auxiliary Machine
FIGURE F.11 – AUXILIARY LEAD TEST LOCATIONS ON BACK OF CONTROL PANEL
STATOR VOLTAGE TEST (CONTINUED)
TROUBLESHOOTING AND REPAIR
F-35
F-35
VANTAGE® 500
3A
236A
238B
CB3
CB5
CB1
CB4
CB6
CB2
42B
6B
11
32A
12
5C
GND-C
5E
GND-D
8
9
5B
J11
J10
GND-E
J12
32
42A
Back of Control Panel
Typical 1Ø Auxiliary Machine