Test table f.2, Diode test rectifier terminal connections, Troubleshooting and repair – Lincoln Electric VANTAGE SVM178-B Manuel d'utilisation

Page 229: Output rectifier bridge test (continued)

Advertising
background image

OUTPUT RECTIFIER BRIDGE TEST(CONTINUED)

TROUBLESHOOTING AND REPAIR

F-41

F-41

VANTAGE® 500

TABLE F.2 – DIODE TEST TABLE

AC1

DC(+)

Forward Bias

(Low Resistance)

AC2

DC(+)

Forward Bias

(Low Resistance)

AC3

DC(+)

Forward Bias

(Low Resistance)

DC(-)

AC1

Forward Bias

(Low Resistance)

DC(-)

AC2

Forward Bias

(Low Resistance)

DC(-)

AC3

Forward Bias

(Low Resistance)

AC1

DC(-)

ReverseBias

(High Resistance)

AC2

DC(-)

ReverseBias

(High Resistance)

AC3

DC(-)

ReverseBias

(High Resistance)

DC(+)

AC1

ReverseBias

(High Resistance)

DC(+)

AC2

ReverseBias

(High Resistance)

DC(+)

AC3

ReverseBias

(High Resistance)

DIODE TEST

RECTIFIER

TERMINAL

CONNECTIONS

TEST INSTRUMENT

(+) Lead

(-) Lead

DIODE BIAS

& EXPECTED

TEST RESULT

18. Reconnect all leads.

19. Perform the Case Cover Replacement Procedure.