11-2 Signal input/output terminals

11 OTHER (contd.)

Terminals

[CAM SW OUT] camera
switching signal output

[ALARM IN 1] alarm
signal input

[ALARM RESET] alarm
signal reset input

[CLOCK RESET OUT]
clock reset output

[CLOCK RESET IN]
clock reset input

[EXT REC IN] external
automatic recording
signal input

[HDD FULL OUT] HDD
full signal output

Signal level

Remarks

Open collector
output

Ground input

High input
About 47 kohms

Ground output

Ground input

Ground input

Ground output
Output imped-
ance of 1 kohm
or less

5 ms

GND

CAN SW OUT

Ref.Sig

1

st

field

2

nd

field

1

st

field

2

nd

field

Min. 400 ms

Min. 400 ms

2.5 s to 3.0 s

High voltage = 5 V

High voltage = 5 V to 12 V

Min. 400 ms

Min. 400 ms

Min. 400 ms

Low voltage = 0 V

High voltage = 5 V

Low voltage = 0 V

High voltage = 5 V

Low voltage = 0 V

High voltage = 5 V

Low voltage = 0 V

High voltage = 5 V

Low voltage = 0 V

(When menu switch <REC
SPEED> is set to "30")

Advertising