2.3 GENERAL

INFORMATION

4.1B

The installation must conform with local codes or, in

absence of local codes, the National Gas and Propane

Installation Code CSA B149.1 in Canada, or the National

Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United

States. Suitable for mobile home installation if installed in

accordance with the current standard CAN/CSA Z240MH

Series, for gas equipped mobile homes, in Canada or

ANSI Z223.1 and NFPA 54 in the United States.

As long as the required clearance to combustibles is

maintained, the most desirable and benefi cial location

for an appliance is in the center of a building, thereby

allowing the most effi cient use of the heat created. The location of windows, doors and the traffi c fl ow in the

room where the appliance is to be located should be considered. If possible, you should choose a location

where the vent will pass through the house without cutting a fl oor or roof joist.

If the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood

fl ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth.

Some appliances have optional fans or blowers. If an optional fan or blower is installed, the junction box must

be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA 70 National Electrical code in the United States.

We suggest that our gas
hearth products be installed
and serviced by professionals
who are certified in the U.S.
by the National Fireplace
Institute

® (NFI) as NFI Gas

Specialists

www.nficertified.org

GDS25

NG

LP

Altitude (FT)

0-4,500

0-4,500

Max. Input (BTU/HR)

24,500

23,000

Max. Output (BTU/HR)

19,600

18,400

Effi ciency (w/the fan on)

80%

80%

Min. Inlet Gas Supply Pressure

4.5" Water Column (11.2mb)

11" Water Column (27.4mb)

Max. Inlet Gas Supply Pressure

7" Water Column (17.4mb)

13" Water Column (32.4mb)

Manifold Pressure (Under Flow Conditions)

3.5" Water Column (8.7mb)

10" Water Column (25mb)

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
AND QUALITY!

When the appliance is installed at elevations above 4,500ft (1371.6m), and in the absence of specifi c

recommendations from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at

the rate of 4% for each additional 1,000ft (304.8m).

Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible

for use with other gases, unless a certifi ed kit is used.

The blower power cord must be connected into a properly grounded receptacle. The grounding prong must not

be removed from the cord plug.

This appliance is approved for closet or recessed installations, as well as for bathroom, bedroom and

bed-sitting room installations and is suitable for mobile home installations. The natural gas model can be

installed in a mobile home that is permanently positioned on its site and fueled with natural gas.