7 vertical termination – Napoleon Fireplaces Bayfield - GDS25 Manuel d'utilisation

Page 15

Advertising
background image

(H

T

) < (V

T

)

Simple venting configurations.

See graph to determine the required vertical rise V

T

for the

required horizontal run H

T

.

REQUIRED

VERTICAL

RISE IN FEET

(METERS) V

T

HORIZONTAL VENT RUN PLUS OFFSET IN FEET (METERS) H

T

For vent configurations requiring more than one 45° and one 90° elbow, the following formulas apply:
Formula 1: H

T

< V

T

Formula 2: H

T

+ V

T

< 40 feet (12.2m)

Example:
V

1

= 5 FT (1.5m)

V

2

= 10 FT (3.1m)

V

T

= V

1

+ V

2

= 5 FT (1.5m) + 10 FT (3.1m) = 15 FT (4.6m)

H

1

= 3 FT (0.9m)

H

2

= 2.5 FT (0.8m)

H

R

= H

1

+ H

2

= 3FT (0.9m) + 2.5FT (0.8m) = 5.5 FT (1.7m)

H

O

= .03 (one 45° + three 90° elbows - 135°)

= .03 (45 + 270 - 135°) = 5.4 FT (1.6m)
H

T

= H

R

+ H

O

= 5.5 FT (1.7m)+ 5.4 FT (1.m) = 10.9 FT (3.3m)

H

T

+ V

T

= 10.9 FT (3.3m)+ 15 FT (4.6m) = 25.9 FT (7.9m)

Formula 1:

H

T

< V

T

10.9FT (3.3m) < 15 (4.6m)

Formula 2:

H

T

+ V

T

< 40 FT (12.2m)

25.9FT (7.9m) < 40 (12.2m)

Since both formulas are met, this vent configuration is acceptable.

The shaded area within the lines represents acceptable

values for H

T

and V

T

0

5

(1.5)

10

(3.1)

15

(4.6)

20

(6.1)

40 (12.2)

10 (3.1)

20 (6.1)

30 (9.1)

3 (0.9)

18.3A

90°

V

1

H

1

H

2

90°

90°

45°

V

2

3.7 VERTICAL

TERMINATION

W415-0547 / J / 07.16.13