6.0 OPTIONAL BLOWER INSTALLATION

!

WARNING

RISK OF FIRE AND ELECTRICAL SHOCK.

TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.

USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH

THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS

COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL

VOID THE WARRANTY AND CERTIFICATION.

BLOWER
A.

Cut and remove the tie securing the blower switch wires
to the heat shield.

B.

Connect the white wire coming from below the appliance
to the terminal on the blower.

C.

Connect the black blower wire to the black wire coming
from below the appliance.

D.

Insert the clips on the blower housing into the cutouts in
the rear shield. Push down to lock the clips into position.

E.

Secure the blower using the screw and lock washer
supplied.

NOTE: Ensure
that all the wires
are tucked into
the blower switch
housing.

SWITCHES

F.

Open the switch housing by removing the top screw.

G.

Install the thermodisc bracket as shown, using 2 of the screws
supplied. Connect the fl agged leads to the terminals of the
thermodisc.
Remove the knock out from the housing label.

H.

Install the variable speed switch (rheostat) into the housing
with the wires facing up. Secure the switch to the housing
using the pal nut and the knob supplied.

I.

Connect the male connector on the switch to the female
connector coming from the appliance.

J.

Tuck all of the wires into the housing and close. Secure using
the screw removed in step F.